Hitachi L300P Series Service Manual page 12

Hitachi inverter service manual
Hide thumbs Also See for L300P Series:
Table of Contents

Advertisement

Function mode
Code
Function name
Option1 operation selection
P001
on error
Option2 operation selection
P002
on error
P010
Feed-back option selection
Encoder pulse number
P011
setting
P012
Control mode selection
Pulse train input mode
P013
selection
Orientation stop position
P014
setting
P015
Orientation speed setting
Orientation direction
P016
selection
Orientation completion range
P017
setting
Orientation completion delay
P018
time setting
Electronic gear position
P019
selection
Electronic gear numerator of
P020
ratio setting
Electronic gear denominator
P021
of ratio setting
Position control feed-forward
P022
gain setting
Position control loop gain
P023
setting
Compensation of secondary
P025
resistor selection
Over-speed detect level
P026
setting
Speed-error over detect level
P027
setting
Digital input option input
P031
mode selection ( Acc/Dec)
Stop
position
setting
P032
orientation
input
selection
DeviceNet running order of
P044
monitoring timer setting
Setting in action of abnormal
P045
communication
Output
assemble
instance
P046
Number setting
Input
assemble
instance
P047
Number setting
Detect
of
idol
mode
P048
motion setting
P049
Pole setting of rotation speed
U001
User1 selection
U002
User2 selection
U003
User3 selection
U004
User4 selection
U005
User5 selection
U006
User6 selection
U007
User7 selection
U008
User8 selection
U009
User9 selection
U010
User10 selection
U011
User11 selection
U012
User12 selection
(Note 1) P044-P049 are displayed on a 0.4-55kW model.
128.-9999./1000-6500(10000-65000) (pulse)
00(ASR mode)/01(APR mode)
00(Mode 0)/01(Mode 1)/02(Mode 2)/03(Mode 3)
0.00-99.99/100.0-120.0(Hz)
00(Forward)/01(Reverse)
0.-9999./1000(10000) (pulse)
00(Feedback)/01(Reference)
0.00-99.99/100.0-150.0(%)
0.00-99.99/100.0-120.0(Hz)
00(operator)/01(option1)/02(option2)
for
mode
00(operator)/01(option1)/02(option2)
00(trip)/01(trip after deceleration stop)/02(invalid)/
03(free-run)04(deceleration stop)
for
00(trip)/01(trip after deceleration stop)/02(invalid)/
03(free-run)04(deceleration stop)
no/d001-P049 <-P032>
no/d001-P049 <-P032>
no/d001-P049 <-P032>
no/d001-P049 <-P032>
no/d001-P049 <-P032>
no/d001-P049 <-P032>
no/d001-P049 <-P032>
no/d001-P049 <-P032>
no/d001-P049 <-P032>
no/d001-P049 <-P032>
no/d001-P049 <-P032>
no/d001-P049 <-P032>
SJ300 Setting range
00(TRP)/01(RUN)
00(TRP)/01(RUN)
00(Invalid)/01(Valid)
0.-4095.
0.00-9.99(s)
0.-9999.
0.-9999.
0.00-99.99/100.0-655.3
0.00-99.99/100.0
00(Invalid)/01(Valid)
0.00-99.99s
20,21,100
70,71,101
0-38(even only)
1- 9
Initial data
Note
-FE/-FU/-F
00
00
00
1024
00
00
0.
5.00
00
5
0.00
00
1.
1.
0.00
0.50
00
135.0
7.50
00
00
1.00
0.
21
71
01
0
no
no
no
no
no
no
no
no
no
no
no
no

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sj300 series

Table of Contents