Transmitter Location, Clearance & Fixing - Worcester DT10RF Instruction Manual

Hide thumbs Also See for DT10RF:
Table of Contents

Advertisement

All manuals and user guides at all-guides.com
50mm
D
70mm
6
TRANSMITTER LOCATION
CLEARANCES & FIXING
1
A
Digistat Optimiser
SET?
SELECT
YES
1.5m (5’)
B
3
1
2
3
D
2
C
FITTING & OPERATING INSTRUCTIONS FOR WORCESTER BOSCH
DT10RF PROGRAMMER & DT10RF OPTIMISING PROGRAMMER
8-716-106-652 issue c (01.05) UK
TRANSMITTER LOCATION
CLEARANCES & FIXING
Transmitter location:
1 Position the transmitter (A) as close
to the main living area as possible
onto a flat inside wall, approx. 1.5m
(5') above the floor within max. signal
range of the appliance receiver.
Keep the transmitter away from:
light and heat sources
enclosures and curtains
direct draughts, including fans, air
vents, windows and doors
damp and condensation
Replacing a mains wired unit:
Isolate the main electric supply. Refer
to the manufacturers instructions to
remove the unit. Isolate the existing
wiring and make electrically safe.
Transmitter clearances:
See diagram opposite for minimum area
required for operation.
Transmitter fixing:
SAFETY: All relevant safety
precautions must be undertaken.
Protective clothing, footwear, gloves
and safety goggles must be worn
as appropriate.
CAUTION: Ensure there are no
pipes, electric cables or other
hazards before drilling.
2 Loosen screw (C) on transmitter to
remove the baseplate (B)
3 Hold baseplate (B) level to mark
securing points (D) and remove
baseplate (B)
4
Drill holes to marks
Fit one wall plug into each hole
Reposition baseplate (B), check
level and secure with screws supplied
Refit the transmitter to the baseplate
(B) and tighten screw (C) to secure.

Advertisement

Table of Contents
loading

Table of Contents