Fitting The Receiver - Worcester DT10RF Instruction Manual

Hide thumbs Also See for DT10RF:
Table of Contents

Advertisement

All manuals and user guides at all-guides.com
B
A
1
C
E
E
B
A
C
E
4

FITTING THE RECEIVER

FITTING THE RECEIVER
2
D
3
4
1 Release securing screw (A)
H
2 Pull cover panel (B) upwards to
3 Grip tab (C), pull upwards to
5
G
4 Align connector pins (F) into
F
5 Feed the ribbon cable (G) into
7
6 Align programmer (E) and locate
6
D
7 Locate cover panel (B) and secure
FITTING & OPERATING INSTRUCTIONS FOR WORCESTER BOSCH
DT10RF PROGRAMMER & DT10RF OPTIMISING PROGRAMMER
8-716-106-652 issue c (01.05) UK
DANGER - 24V &
230V:
DO NOT TOUCH
THE ELECTRICAL
COMPONENTS OR
CIRCUITS.
CAUTION: ISOLATE THE MAINS
ELECTRICITY SUPPLY BEFORE
STARTING ANY WORK AND
OBSERVE ALL RELEVANT
SAFETY PRECAUTIONS.
OBSERVE ELECTRONIC STATIC
DISCHARGE PRECAUTIONS.
DO NOT TOUCH THE PCB
CIRCUITS
Important: Switch off boiler
Remove boiler outer casing and
control panel fascia to gain access
to the heatronic control panel
remove
disengage clips (D) and pull
forwards to remove blanking plate
(E) or existing programmer
receptors (G) in the pcb and push
fully home
recess (H)
clips (D), push into slots then
downwards to secure using grip
tab (C)
with screw (A)
Replace fascia cover and outer
casing before switching on the
electricity supply and boiler
Switch boiler on when completed.
Refer to ‘USERS INSTRUCTIONS’
section for details of pre-set and
setting programs.