Download Print this page

Goodman SS-CPC36-72 Specifications page 35

Cpc commercial 3- to 6-ton packaged air conditioners 13 seer / 11.3 eer single-phase & three-phase

Advertisement

w
d
— CpC060*3d
iring
iagram
SMOKE/FIRE DETECTOR
REPLACES JUMPER
BK
RD
GR
WH
YL
TB1
1
5
OR
BR
YL
WH
PU
OR
BR
YL
WH
PU
3
4
5
1 2
EM
C
L
G
N
GR
BL
BK
RD
L1
SUPPLY VOLTAGE
208-240/1/60
C
T2
T2
C
T1
T1
T3
COMP
C
F
RCCF
CM
L
N
EM
G
208-240V
SEE NOTE 3
3
24V
TB1
4
5
6
PLF
HPS
Y/
TB1
W1
Y1
O
R
W2
Y2
THERMOSTAT
SS-CPC36-72
(s
p
, d
ingle
hase
ireCt
RD
BK
TB1
2
3
1
BL
S2
S1
240
C
208
TR
PK
24V
RD
BL
BR
RD
WH
PU
3
6
9
C
F
RCCF
2
5
8
1
4
7
PLF 1
L3
L2
C
CM
COMP
C
T3
EM
GND
HPS
LPS
LVJB
PLF
RCCF
TB1
TR
NOTES:
1. REPLACEMENT WIRE MUST BE SAME SIZE AND
TYPE INSULATION AS ORIGINAL (AT LEAST
105°C) USE COPPER CONDUCTOR ONLY.
1
2. TO CHANGE EVAPORATOR MOTOR SPEED MOVE
WHITE AND YELLOW LEADS FROM "3" AND "4"
TR
TO "4" AND "5". IF BOTH LEADS ARE ENERGIZED,
THE HIGHER SPEED SETTING IS USED.
3. FOR 208 VOLT TRANSFORMER OPERATION
MOVE BLACK WIRES FROM TERMINAL 3 TO
TERMINAL 2 ON TRANSFORMER.
4. USE COPPER CONDUCTORS ONLY ++ USE N.E.C.
5
N
4
CLASS 2 WIRE
3 EM G
L
5. ECONOMIZER PLUG LOCATED IN THE RETURN
2
C
1
AIR COMPARTMENT. REMOVE MALE PLUG AND
TB1
ATTACH FEMALE PLUG TO ECONOMIZER
ACCESSORY.
SEE NOTE 2
LPS
C
PLF2
4
6
5
3
2
1
SEE UNIT RATING PLATE FOR TYPE AND SIZE
G
C
SEE NOTE 5
www.goodmanmfg.com
d
)
rive
BL
RD
BL
BK
RD
T3
L3
T2
L2
RD
YL
BK
T1
L1
BK
C
YL
YL/PK
PLF 2
GR
YL
PU
PU
YL
RD
GR
GR
WH
WH
BR
BR
BL
BL
OR
TB1
BL
BK
YL
BK
RD
PU
BK
BR
YL
T3
T1
T2
CM
COMP
LPS
208-240/3/60 0140L0 0428 REV B
COMPONENT LEGEND
CONTACTOR
CONDENSER MOTOR
COMPRESSOR
EVAPORATOR MOTOR
EQUPIMENT GROUND
HIGH PRESSURE SWITCH
LOW PRESSURE SWITCH
LOW VOLTAGE JUNCTION BOX
FEMALE PLUG / CONNECTOR
RUN CAPACITOR FOR
CONDENSER FAN
TERMINAL BLOCK (24V SIGNAL)
TRANSFORMER
OF OVER CURRENT PROTECTION
208-240/3/60 0140L0 0428 REV B
p
s
rodUCt
peCifiCations
RD
2
0
BK
8
-
2
4
0
/
3
/
6
0
GND
YL
OR
3 6
2
5
1
4
YL
BL
LVJB
T
Y1
H
Y/Y2
E
R
R
G
M
W1
O
W2
S
C
T
O
A
T
++
CONTROL
YL/PK
BOX
HPS
FACTORY WIRING
LINE VOLTAGE
LOW VOLTAGE
OPTIONAL
HIGH VOLTAGE
FIELD WIRING
HIGH VOLTAGE
LOW VOLTAGE
WIRE CODE
BK BLACK
BL BLUE
BR BROWN
GR GREEN
OR ORANGE
PK PINK
PU PURPLE
RD RED
WH WHITE
YL YELLOW
BL/PK BLUE WITH PINK STRIP
YL/PK YELLOW WITH PINK STRIP
THERMOSTAT
FIELD WIRING
NO ECONOMIZER
W
WH
W
G
GR
G
R
RD
R
Y1
YL
Y/Y2
Y2
C
BL
C
OR
O
O
STAT
TB1
WITH ECONOMIZER OPTION
W
WH
W
G
GR
G
R
RD
R
YL
Y1
Y
Y/Y2
C
BL
C
OR
O
O
STAT
TB1
2 STAGE COOLING
W
WH
W
G
GR
G
R
RD
R
Y1
YL
Y1
Y/Y2
PK
Y2
C
BL
C
OR
O
O
STAT
TB1
35

Hide quick links:

Advertisement