Cpc commercial 3- to 6-ton packaged air conditioners 13 seer / 11.3 eer single-phase & three-phase

Advertisement

p
s
rodUCt
peCifiCations
w
d
CpC036/48*1d (s
iring
iagram
BR
RD
GR
G
EBTDR
BL
NO
R
K1
XFMR-R
COM
XFMR-C
K1
SEE
C
BK
NOTE #2
NC
SPEED
M1
M2
UP
BK
SMOKE/FIRE DETECTOR
REPLACES JUMPER
BL
BK
1
BK
3
2
PU
BIR
BK
RD
BL
PU
PU
EM
BR
BL
3 SPEED
RD
BK
BC
PU
L1
SUPPLY VOLTAGE
208-240/1/60
C
T2
R
C
T1
C
S
COMP
C
H
RCCF
F
CM
EM
BR
EBTDR
208-240V
SEE NOTE 3
3
24V
TB1
BR
4
5
6
PLF
R
G
R
Y/
W1
Y1
O
R
W2
Y2
XFMR
C
THERMOSTAT
TB1
EBTDR
30
p
, d
ingle
hase
ireCt
PU
RD
BK
BK
1
2
3
240
C
208
TR
BL
24V
RD
BL
PK
BL
BR
S2
S1
TB1
RD
BR
RD
WH
PU
3
6
9
C
H
F
RCCF
2
5
8
1
4
7
YL
PLF 1
BR
EM
BC
PU
3 SPEED
RD
ALTERNATE
MOTOR
6-WIRES
SEE TABLE 1
L2
COMPONENT LEGEND
BC
BIR
C
CM
COMP
EM
GND
HPS
LPS
PLF
RCCF
TB1
TR
NOTES:
1. REPLACEMENT WIRE MUST BE SAME SIZE AND
TYPE INSULATION AS ORIGINAL (AT LEAST
105°C) USE COPPER CONDUCTOR ONLY.
2. TO CHANGE EVAPORATOR MOTOR SPEED MOVE
M1 OR M2 WIRE TO COM TERMINAL ON EBTDR
1
AND PLACE WIRE REVMOVED FROM COM ON
EMPTY M1 OR M2 TERMINAL.
TR
3. FOR 208 VOLT TRANSFORMER OPERATION
MOVE BLACK WIRES FROM TERMINAL
3 TO TERMINAL 2 ON TRANSFORMER.
4. USE COPPER CONDUCTORS ONLY ++ USE N.E.C.
CLASS 2 WIRE
5. ECONOMIZER PLUG LOCATED IN THE RETURN
AIR COMPARTMENT. REMOVE MALE PLUG AND
ATTACH FEMALE PLUG TO ECONOMIZER
ACCESSORY.
6. DIAGRAM SHOWS FACTORY SPEED TAP SETTINGS.
LPS
C
ALTERNATE MOTOR WIRING
COLOR
RD
PLF2
HPS
BK
6 5 4
BL
3
2
1
PU
SEE UNIT RATING PLATE FOR TYPE AND SIZE
G
C
SEE NOTE 5
www.goodmanmfg.com
d
)
rive
RD
BL
BL
BK
T2
L2
RD
RD
BK
T1
L1
BK
C
BK
YL/PK
PLF 2
GR
YL
PU
PU
YL
RD
PU
GR
GR
WH
BR
BR
OR
BL
BL
TB1
BL
BK
BK
RD
YL
BK
BR
YL/PK
T3
T2
T1
CM
COMP
LPS
BLOWER CAPACITOR
BLOWER INTERLOCK RELAY
CONTACTOR
CONDENSER MOTOR
COMPRESSOR
EVAPORATOR MOTOR
EQUPIMENT GROUND
HIGH PRESSURE SWITCH
LOW PRESSURE SWITCH
FEMALE PLUG / CONNECTOR
RUN CAPACITOR FOR
CONDENSER FAN
TERMINAL BLOCK (24V SIGNAL)
TRANSFORMER
TABLE 1
TABLE 2
SPEED TAPS
TERMINATION
LOW
RD
COM (EBTDR)
BL
MED
M1 (EBTDR)
BK
HIGH
M2 (EBTDR)
PIN 1 (24V XFMR)
OF OVER CURRENT PROTECTION
208-240/1/60 0140L00504 REV A
2
0
8
PB
-
2
4
0
/
1
/
6
0
GND
YL
OR
3 6
2
5
1
4
YL
BL
T
Y1
H
Y/Y2
E
R
R
G
M
W1
O
W2
S
O
T
C
A
T
++
CONTROL
BL/PK
BOX
HPS
FACTORY WIRING
LINE VOLTAGE
LOW VOLTAGE
OPTIONAL
HIGH VOLTAGE
FIELD WIRING
HIGH VOLTAGE
LOW VOLTAGE
WIRE CODE
BK BLACK
BL BLUE
BR BROWN
GR GREEN
OR ORANGE
PK PINK
PU PURPLE
RD RED
WH WHITE
YL YELLOW
BL/PK BLUE WITH PINK STRIP
YL/PK YELLOW WITH PINK STRIP
THERMOSTAT
FIELD WIRING
NO ECONOMIZER
W
WH
W
G
GR
G
R
RD
R
Y1
Y/Y2
YL
Y2
C
BL
C
OR
O
O
STAT
TB1
WITH ECONOMIZER OPTION
W
WH
W
G
GR
G
R
RD
R
Y1
YL
Y
Y/Y2
C
BL
C
OR
O
O
STAT
TB1
2 STAGE COOLING
W
WH
W
G
GR
G
R
RD
R
Y1
YL
Y1
PK
Y2
Y/Y2
C
BL
C
OR
O
O
STAT
TB1
SS-CPC36-72