IEC61162-1 (NMEA) equipment
Connects a navigator to the terminal box in the transceiver unit. The FS-1570/2570 can
receive the following sentences in IEC-61162-1 (ed.2nd) format. Use the interconnection
cable type CO-SPEVV-SB-C 0.2x2P (option).
GLL: Latitude and longitude
RMC: Generic navigation information
GGA: GPS position, UTC
ZDA: UTC, day, month, and year
RMA: Minimum Loran-C data
Priority: GGA>RMC>GLL
Distress alert IC-302
Use CO-SPEVV-SB-0.2x5P cable (option). For the fabrication, see the figure in below.
Indicator IC-303
Use CO-SPEVV-SB-C 0.2x5P cable (option) and fabricate it as below.
Outer sheath
Fabrication of CO-SPEVV-SB-C for connect to the transceiver unit
2-6
Priority is kept for one minute.
90
Remove the outer sheath and
Inner sheath
armor by 90 mm.
11
9
Remove the inner sheath by 20 mm,
and the sheath of the cores by 9 mm.
Twist and trim the shield.
Vinyl wire
Cut the unused cores.
Solder a vinyl wire to the shield.