6. Press [ ] [ ] to select ROLL ANGLE or PITCH ANGLE.
7. Press [ ] [ ] to adjust (-10 to +10 ).
By using a clinometer or other means, measure ship's semi-permanent inclination angle. Take
the polarity of the angle as follows. For example, if the stern is 3 down, set -3 .
ROLL ANGLE
PITCH ANGLE Stern up
8. Press the [MENU] key several times to close the menu.

3.5 System Back Up

After setting the equipment follow the procedure below to back up system settings. Backup data
can be loaded in the event of equipment trouble, to restore previous system settings.
1. Press the [MENU] key to display the user menu.
2. Press the cursor pad to select SYS at the top of the menu.
MENU
GO TO SYS MENU
: SELECT
3. Press [ ] to select GO TO SYS MENU.
4. Press [ ] to select YES.
The system menu appears.
+
0
+
Starboard up
COM1 COM2 HORZ VERT
YES
MENU: END
: CHANGE
Display to select the system menu
38
+
0
-
Starboard down
Stern down
ES
SHORT-CUT
NO
SYS