Furuno SEARCHLIGHT CH-250 Installation Manual page 14

Searchlight sonar
Hide thumbs Also See for SEARCHLIGHT CH-250:
Table of Contents

Advertisement

Flush mounting for control unit Type:
OP02-83-1.5, Code no.: 001-413-600 (1.5 m cable)
OP03-83-5, Code no.: 001-413-610 (5m cable)
Name
Fixing metal
Self-tapping screw
Hex. bolt
Cable assembly
1. Make holes at the place to mount (W287 x H87).
2. Fasten the fixing metal to the control unit with two hex. bolts (supplied as option).
3. Fasten the fixing metal assembled at step 2 to holes made at step 1 with four tapping
screws (supplied as option).
1.1.3
Blackbox type
The blackbox type is required to connect a standard VGA monitor via the interface unit IF-8000.
Supply monitor and interconnection cable (Max. length 15 m with Dsub-15P connectors of male,
three rows of 15 pins) locally. The monitor used should satisfy the specifications shown below.
VGA type
ANALOG RGB 0.7 Vpp, positive polarity
TLL level H, V, Negative polarity
Fixing Metal
Type
06-021-2101-2
100-279-732-10
5x20
000-162-609-10
M4x12
000-162-939-10
MJ-A10SPF0002-0
000-142-878
15
MJ-A10SPF0002-0
000-131-411
50
Fixing metal
Hex. Bolts
Code No.
Qty
1
4
2
1
1
Hex. Bolts
4
Remarks
1.5 m
Select one.
5 m