Flush mounting
Flush mounting for unibody (Type: OP06-16, Code no.: 006-556-300)
Name
Fixing metal
Self-tapping screw
Hex. bolt
1. Make holes at the place to mount (W287 x H297).
2. Fasten monitor and control units with the fixing metal (supplied as option) and four hex.
bolts (supplied as option).
3. Fasten the fixing metal assembled at step 2 to holes made at step 1 with six tapping screws
(supplied as option).
Flush mounting for monitor unit (Type: OP06-17, Code no. 006-556-310)
Name
Fixing metal
Self-tapping screw
Hex. bolt
1. Make holes at the place to mount (W287 x H207).
2. Fasten the fixing metal (supplied as option) to the monitor unit with four hex. bolts (M4x12,
supplied as option).
3. Fasten the fixing metal assembled at step 2 to holes made at step 1 with four tapping
screws (5x20, supplied as option).
Type
06-021-1311-2
100-279-612-10
5x20
000-162-609-10
M4x12
000-162-939-10
Fixing metal
Type
Code No.
06-021-1321-2
100-279-622-10
5x20
000-162-609-10
M4x12
000-162-939-10
3
Code No.
Qty
1
6
4
Hex. Bolts
Qty
1
4
4
Remarks