This unit is set at factory to operate from 220-230 VAC ship's mains. For connection to a 100
VAC, 110-115 VAC, 200 VAC or 24 VDC ship's mains, modify the connections in the distribution
box as shown below.
Note: Tick the appropriate box on the inside of the FE-702 distribution box cover to denote the
power use.
100 VAC, 110-115 VAC, 200 VAC Ship's Mains
1.
Connect the power cable to #1 & #3 on TB5 in the distribution box.
2.
Modify the wiring at TB7 according to ship's mains as shown in the table below.
Ship's mains
220-230 VAC
(Default)
200 VAC
110-115 VAC
100VAC
3. CHANGING POWER
200-230 VAC (50/60 Hz)
100-115 VAC (50/60 Hz)
24 VDC
Label inside the distribution box FE-702
TB7 #1
TB7 #2
Orange
Red
Orange
Black
Brown
SPECIFICATIONS
TB7 #3
Red
Black
Black
Red
Orange
Red
Black
20
TB7 #4
TB7 #5
Brown
White
Brown
White
Brown
White
Orange
White