2. WIRING

The MFDBB, MFD8, MFD12 or PSU-012 connects to the radar sensor with the two-way cable
MOD-ASW0001 (MOD-ASW0002 for DRS25A).In order to minimize the chance of picking up
electrical interference, avoid where possible routing the two-way cable near other onboard elec-
trical equipment. After passing the cable through the hole in the radar sensor, apply sealing com-
pound around the hole for waterproofing. When connecting to other NMEA2000 equipment, use
the optional cable M12-05BFFM (φ6) or CB-05BFFM (φ10).
Wiring for DRS2D/4D/4A/6A/12A without PSU-012
RADAR SENSOR
DRS2D/DRS4D
NMEA2000
Equipment
NMEA2000 cable
M12-05BFFM (φ6) or
CB-05BFFM (φ10)
: Standard Supply
: Optional Supply
NOTICE
Before connecting or disconnecting the
NMEA2000 cable, turn off the radar sensor.
The sensor may become damaged if the power is
not turned off.