DRS4A/DRS6A/DRS12A/DRS25A
SAFETY INSTRUCTIONS ............................................................................ i
SYSTEM CONFIGURATION ....................................................................... ii
EQUIPMENT LISTS.................................................................................... iv
1. MOUNTING ............................................................................................ 1
1.1
Mounting Considerations ..............................................................................................1
1.2
Mounting Procedure for DRS2D/4D ............................................................................. 2
1.3
Mounting Procedure for DRS4A/6A/12A/25A ...............................................................3
1.4
2. WIRING .................................................................................................. 9
2.1
Wiring inside DRS2D/4D ............................................................................................12
2.2
Wiring inside DRS4A/6A/12A/25A ..............................................................................16
2.3
Wiring inside Power Supply Unit PSU-013 (for DRS25A) .......................................... 20
2.4
Wiring inside Power Supply Unit PSU-012 (Option)................................................... 21
PACKING LISTS...................................................................................... A-1
OUTLINE DRAWINGS............................................................................. D-1
INTERCONNECTION DIAGRAMS.......................................................... S-1
Installation Manual
RADAR SENSOR
www.furuno.co.jp
DRS2D/DRS4D/

Advertisement

Table of Contents
loading

Summary of Contents for Furuno DRS4A

  • Page 1: Table Of Contents

    EQUIPMENT LISTS... iv 1. MOUNTING ... 1 Mounting Considerations ...1 Mounting Procedure for DRS2D/4D ... 2 Mounting Procedure for DRS4A/6A/12A/25A ...3 Mounting of Power Supply Unit PSU-013 (for DRS25A)/PSU-012 (Option) ...8 2. WIRING ... 9 Wiring inside DRS2D/4D ...12 Wiring inside DRS4A/6A/12A/25A ...16 Wiring inside Power Supply Unit PSU-013 (for DRS25A) ...
  • Page 3: Safety Instructions

    This is possible - Ask your FURUNO representive or dealer to provide this feature. Distance to Model 100 W/m...
  • Page 4: System Configuration

    Multi Function Display BlackBox MFDBB *The power supply unit PSU-012 is necessary in the combination of radar sensor and MFD. DRS2D/4D MFD8 MFD12 MFDBB RADAR SENSOR DRS4A/DRS6A/DRS12A Power Supply Unit PSU-012* Multi Function Display RECTIFIER RU-1746B 12-24 VDC 100/110/220/230 VAC...
  • Page 5 DRS25A RADAR SENSOR DRS25A NMEA 2000 Equipment Power Supply Unit PSU-013 12-24 VDC Multi Function Multi Function Display Display BlackBox MFD8/12 MFDBB RECTIFIER : Standard Supply RU-1746B : Optional Supply : Local Supply 12-24 VDC 100/110/220/230 VAC...
  • Page 6: Equipment Lists

    Radome, 4 kW, w/CP03-32101 For DRS25A, w/SP03-16101 and CP03-32700 001-025-270 1 set For DRS2D/4D 001-025-780 1 set For DRS4A/6A/12A/25A 000-011-720 Two-way cable, MOD-ASW0001- 100+, 10 m, for DRS2D/4D/4A/6A/12A 000-011-721 Two-way cable, MOD-ASW0001- 150+, 15 m, for DRS2D/4D/4A/6A/12A 000-011-722 Two-way cable, MOD-ASW0001-...
  • Page 7 M12-05BFFM-060 CB-05BFFM-010 CB-05BFFM-020 CB-05BFFM-060 Code No. 1 set 001-025-290 For DRS2D/4D, φ10 NMEA2000 cable 001-025-790 For DRS4A/6A, φ10 NMEA2000 cable 001-035-290 For DRS25A, φ10 NMEA2000 cable 001-025-300 For NMEA2000 connection with a unit 000-167-140-10 For LAN cable extension 000-167-175-10 000-167-176-10...
  • Page 8: Mounting

    The radar sensor must not be mounted where the temperature is more than 55 degrees centigrade. As shown in the figure below, the radar sensor may be installed on a common mast or on the radar mast. (a) Common mast (b) Radar mast For DRS4A/6A/12A...
  • Page 9: Mounting Procedure For Drs2D/4D

    Radar sensor Radar sensor Mounting Procedure for DRS2D/4D 1. Remove mounting hardware at the bottom of the radar sensor, four each of hex bolts (M10x20), spring washers and flat washers. Save the spring washers and flat washers to use them to fix the radome base to the platform, at step 3. If the thickness of the mounting platform is 5 mm or less, also save the bolts.
  • Page 10: Mounting Procedure For Drs4A/6A/12A/25A

    4. Mount the cover tentatively. The cover is opened for wiring at Chapter 2. Mounting Procedure for DRS4A/6A/12A/25A Refer to the outline drawing at the back of this manual, and drill five holes in the mounting platform: four holes of 15 mm in diameter for fixing the radar sensor and one hole of 25-30 mm in diameter for the signal cable.
  • Page 11 5. Coat the hex bolts (4 pcs.) with silicone sealant. Fasten the antenna radiator to the radiator bracket with the hex bolts, flat washers and spring washers supplied with the radiator. Radiator bracket Spring washer 1.3.2 Mounting the radar sensor The radar sensor can be mounted using the fixing holes on the outside (200 x 200 mm) or inside (140 x 150 mm) the radar sensor.
  • Page 12 2. Lay the radar sensor on the mounting platform, orienting it as shown below. (The hinges must face toward the stern.) STERN Do not lift the radar sensor by the radiator; lift it by the housing. The radiator may be damaged. 3.
  • Page 13 4. Pass flat washers (M12, supplied), spring washers (M12, supplied) and nuts (M12, supplied) onto hex. bolts. Fasten by tightening nuts. Do not fasten by tightening the hex. bolts; seal washers may be damaged. Rubber mat 5. Coat flat washers, spring washers, nuts and exposed parts of bolts with anticorrosive sealant. 6.
  • Page 14 Using inside fixing holes of the sensor housing If this radar is replacing a FURUNO radar whose mounting dimensions are the same as this one (140 x 150 mm), it may be possible to use its mounting platform. This method requires removal of the RF unit from the radar sensor to access inside fixing holes.
  • Page 15: Mounting Of Power Supply Unit Psu-013 (For Drs25A)/Psu-012 (Option)

    Do not install the power supply unit on the overhead; install it on the deck or bulkhead. Use four tapping screws (4x20, supplied) to fasten the power supply unit. Self-tapping screw (4x20, 4 pcs.) DRS4A DRS6A Contents of PSU-0012/013 Type Code No.
  • Page 16: Wiring

    NMEA2000 cable M12-05BFFM (φ6) or CB-05BFFM (φ10) : Standard Supply : Optional Supply To Multi Function Display BlackBox MFDBB or Multi Function Display NOTICE RADAR SENSOR DRS4A/DRS6A/DRS12A Two-way cable MOD-ASW0001 (10/15/20/30 m) MFD8/12 NMEA2000 cable M12-05BFFM (φ6) or CB-05BFFM (φ10) NMEA2000...
  • Page 17 M12-05BFFM (φ6) or CB-05BFFM (φ10) 12-24 VDC Power cable VL3P-VV-S2X2C-AA050 (supplied with PSU-012) To ship's ground Ground wire (Local supply, IV-2sq) Radar Sensor DRS4A/DRS6A/DRS12A Two-way cable MOD-ASW0001 (10/15/20/30 m) (LAN) (Power) Power Supply Unit PSU-012 LAN cable MOD-Z072 -5 m: supplied...
  • Page 18 Wiring for DRS25A Two-way cable MOD-ASW0002 cable (10/15/20/30 m) Power cable VL3P-VV-S2X2C-AA50 12-24 VDC Ground wire (Local supply, IV-2sq) : Standard Supply : Optional Supply : Local Supply RADAR SENSOR DRS25A NMEA2000 cable M12-05BFFM (φ6) or CB-05BFFM (φ10) (POWER) (LAN) Power Supply Unit LAN cable MOD-2072-050...
  • Page 19: Wiring Inside Drs2D/4D

    Wiring inside DRS2D/4D Two-way cable connection 1. Unfasten three screws at the bottom of the mounting base to remove the fixing plate for the gasket. 2. Remove the gasket, and pass the two-way cable MOD-ASW0001. 3. Fasten the shield of the cable (power) with the cable clamp in the radar sensor, and connect the connector of cable (power) to the power terminal.
  • Page 20 6. Slide the gasket on cables so that the amount of cable above the gasket is lower than the RF chassis. Note: If the two-way cable touches the platform near the mounting base, wind vinyl tape around the cable at the point where it is bent. 7.
  • Page 21 Wind vinyl tape. (supplied) 15 (Area fastened with the cable clamp) 3. Insert wires of cable M12-05BFFM (φ6) or CB-05BFFM (φ10) to the NMEA connector inside the radar sensor, consulting the label on the connector for location. As for shield, use the cable clamp shown below to fasten it to the RF chassis.
  • Page 22 4. Push LAN and POWER cables of the two-way cable and cable M12-05BFFM (φ6) or CB- 05BFFM (φ10) into the slits of the gasket inside the mounting base. Depending on the NMEA2000 cable used, replace the gasket as shown below. Cable type M12-05BFFM (φ6) Gasket...
  • Page 23: Wiring Inside Drs4A/6A/12A/25A

    Wiring inside DRS4A/6A/12A/25A Two-way cable connection If you have no NMEA2000 equipment to connect, use the MOD-ASW0001 cable (standard sup- ply). 1. Open the radar sensor cover by loosening four bolts, and fix the stay for safety purpose. 2. Unfasten four bolts to detach the plate, gasket, washer and lid. Discard the lid at the bottom of the hole for the gasket.
  • Page 24 Fix the power cable at the foil part with this cable clamp. Power cable White Black LAN cable RF unit DRS4A/6A/12A Fix the power cable at the copper foil part with this cable clamp. Gasket Blue Black Power cable DRS25A...
  • Page 25 7. Slide the gasket on cables so that the amount of cable above the gasket is lower than the RF chassis. Washers 8. Push the gasket and washers into the hole at the bottom of the radar sensor, then fasten four pan head screws to fix the plate to the sensor.
  • Page 26 NMEA connector Fasten the drain wire with this screw. RF unit 5. Depending on the NMEA2000 used, replace the gasket as shown below. DRS4A/6A/12A Cable type M12-05BFFM (φ6) Gasket Use the gasket supplied in the plastic bag inside the radar sensor.
  • Page 27: Wiring Inside Power Supply Unit Psu-013 (For Drs25A)

    Wiring of Power Supply Unit PSU-013 (for DRS25A) 1. Detach the body cover by hand. 2. Loosen six pan head screws (M3x8) and slide the shield cover upward to remove it. 3. Unfasten four pan head screws (M14x10) to remove two cable clamps. Pan head screws (M4x10, 4 pcs.) Cable clamps...
  • Page 28: Wiring Inside Power Supply Unit Psu-012 (Option)

    Wiring inside Power Supply Unit PSU-012 (Option) 1. Detach the body cover by hand. 2. Loosen six pan head screws (M3x8) and slide the shield cover upward to remove it. 3. Unfasten two pan head screws (M4x12) to remove the cable clamp. Pan head screw (M4x12, 2 pcs.) Cable clamp...
  • Page 29 工事材料表 INSTALLATION MATERIALS 番 号 名  称 NAME テイコウ組品 RESISTOR ASSEMBLY ミガキ平座金 FLAT WASHER バネ座金 SPRING WASHER 六角スリワリ ボルト HEX.BOLT (SLOTTED HEAD) 型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりませ ん。 TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER PRODUCT.
  • Page 30 RSB-118-092/093/094 工事材料表 INSTALLATION MATERIALS 番 号 名  称 NAME シールワッシャ SEAL WASHER 防蝕ゴム CORROSION-PROOF RUBBER MAT キャップ テイコウ組品 RESISTOR ASSEMBLY バネ座金 SPRING WASHER ミガキマル平座金 FLAT WASHER 六角ナット 1シュ HEX.NUT 六角ボルト(全ネジ) HEX. BOLT ミガキ平座金 FLAT WASHER バネ座金 SPRING WASHER 型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりませ ん。 TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER PRODUCT.
  • Page 31 RSB-118-092/093/094 工事材料表 INSTALLATION MATERIALS 番 号 名  称 NAME 六角ナット 1シュ HEX.NUT 六角ボルト HEX.BOLT アース線 GROUND WIRE 型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりませ ん。 TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER PRODUCT. QUALITY IS THE SAME. (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)...
  • Page 32 RADAR SENSOR 工事材料表 DRS2D/4D INSTALLATION MATERIALS 番 号 名  称 NAME ケーブル組品 CABLE ASSY. ケーブル組品 CABLE ASSY. ケーブル組品 CABLE ASSY. ケーブル組品 CABLE ASSY. 標準は15mであるが必要により選択可 STANDARD LENGTH IS 15M. OTHER LENGTHS ARE ALSO AVAILABLE. 型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりませ ん。 TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER PRODUCT.
  • Page 33 RADAR SENSOR 工事材料表 DRS25A INSTALLATION MATERIALS 番 号 名  称 NAME ケーブル組品 CABLE ASSY. ケーブル組品 CABLE ASSY. ケーブル組品 CABLE ASSY. ケ^ブル組品 CABLE ASSY. 型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりませ ん。 TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER PRODUCT.
  • Page 37 2/Apr/08 R.Esumi...
  • Page 38 Oct.15'07 R.Esumi...
  • Page 44 : +81-(0)798-65-4200 Printed in Japan All rights reserved. Pub. No. IME-35670-B1 (HIMA ) DRS-2D/4D/4A-25A The paper used in this manual is elemental chlorine free. ・FURUNO Authorized Distributor/Dealer A : JAN B1 : APR . 17, 2008 *00016745111* *00016745111* *00016745111* *00016745111*...