3. SETTING AND ADJUSTMENT

After installing the equipment, set up the own ship's static information (MMSI, IMO
number, ship's name, call sign, type of ship and GPS antenna position). Also, set
up the I/O ports.
3.1

Inland AIS Specific Settings

This section shows how to activate and set up the Inland AIS feature. (If you do not
require this feature, go to section 3.2.) The installer obtains the AIS activation key
from the place of purchase.
Entering activation key
Enter your key number to activate the Inland AIS.
1. Press the [MENU] key to open the menu.
2. Select DIAGNOTICS then press the [ENT] key.
3. Select ACTIVATE KEY then press the [ENT] key.
4. Press the [ENT] key, enter your activation key
then press the [ENT] key.
5. Press the [MENU] key to quit.
If you entered the activation key correctly, the
indication "ACTIVATED!" appears then the system is
automatically restarted.
[MENU]
MSG
SENSOR STATUS
INTERNAL GPS
USER SETTINGS
INITIAL SETTINGS
CHANNEL SETTINGS
DIAGNOSTICS
Main menu
[DIAGNOSTICS]
MONITOR TEST
TRANSPONDER TEST
PWR ON/OFF HISTORY
TX ON/OFF HISTORY
MEMORY CLEAR
ACTIVATE KEY
FOR SERVICE
DIAGNOSTICS sub-menu
[ACTIVATE KEY]
DEVICE ID
XX-XX-XX-XX-XX
KEY
-
-
-
QUIT[MENU]
ACTIVATE KEY sub-menu
17

Hide quick links: