Specifications - Furuno IF-NMEASC Operator's Manual

Interface unit
Table of Contents

Advertisement

FURUNO
SPECIFICATIONS OF INTERFACE UNIT
1
INPUT PORT
2
OUTPUT PORT
3
NMEA 0183 OUTPUT INTERVAL
4
POWER SUPPLY
5
ENVIRONMENTAL CONDITIONS
5.1 Ambient Temperature
5.2 Humidity
5.3 Waterproofing
5.4 Vibration
6
COATING COLOR
IF-NMEASC
NMEA 2000*, for data I/O between FURUNO satellite compass SC-30
* NMEA 2000 is a registered trademark of the Nationa l Marine
Electronics Association.
NMEA 0183: Two ports (HDT, HDG, HMD, ATT*, HVE*, VTG, GGA,
RMC, ZDA)
* ATT (heading, pitch, roll) and HVE (heave) are FURUNO
proprietary sentences.
AD-10: One port
Analog: One port (pitch, roll)
HDT, HDG, HDM, ATT, HVE: 25ms, 100 ms, 200 ms, 1 s, 2 s
VTG, GGA, RMC, ZDA: 1 s, 2 s
12-24 VDC: 1.0-0.6 A
-15°C to +55°C
Less than 95% at 40°C
IP20
- From 2 Hz to 5 Hz to up to 13.2 Hz with an excursion of ±1 mm ±10%
-13.2 Hz to 100 Hz with a constant maximum acceleration of 7 m/s
N2.5
SP - 1
IF-NMEASC
2
E7265S02A-M

Advertisement