Advertisement

Quick Links

OPERATOR'S MANUAL
INTERFACE UNIT
IF-NMEASC
MODEL
www.furuno.co.jp

Advertisement

Table of Contents
loading

Summary of Contents for Furuno IF-NMEASC

  • Page 1 OPERATOR'S MANUAL INTERFACE UNIT IF-NMEASC MODEL www.furuno.co.jp...
  • Page 3 • The contents of this manual and equipment specifications are subject to change without notice. • Store this manual in a convenient place for future reference. • FURUNO will assume no responsibility for the damage caused by improper use or modification of the equipment (including software) by an unauthorized agent or a third party.
  • Page 4: Safety Instructions

    - the equipment is emitting strange noises Continued use of the equipment can cause fire or electrical shock. Contact a FURUNO dealer or agent for service. Do not operate the equipment with wet hands. Electrical shock can result. Use the proper fuse.
  • Page 5 IF-NMEASC 1.05 m Warning labels are attached to the equipment. Do not remove these labels. If a label is missing or illegible, contact a FURUNO agent or dealer about replacement. WARNING Name: Warning Label (1) To avoid electrical shock, Type: 86-003-1011-1 do not remove cover.
  • Page 6: Table Of Contents

    TABLE OF CONTENTS FOREWORD ...v SYSTEM CONFIGURATION ...vi MOUNTING ...1 1.1 Equipment List ... 1 1.2 Mounting Procedure... 1 WIRING ...2 ADJUSTMENTS...4 3.1 LEDs and Equipment Status ... 4 3.2 Setting Up NMEA Ports... 5 3.3 Heading, Pitch and Roll Offsets ... 8 OPERATION ...9 MAINTENANCE, TROUBLESHOOTING...10 5.1 Preventive Maintenance...
  • Page 7: Foreword

    Thank you for considering and purchasing FURUNO equipment. Features The IF-NMEASC is a dedicated interface unit for the SC-30 Satellite Compass. It receives NMEA ® 2000 * format heading, pitch, roll and GPS position data from the SC-30, converts them to NMEA 0183 format data and outputs the converted data to external equipment.
  • Page 8: System Configuration

    SYSTEM CONFIGURATION Radar AD-10 Current Indicator Scanning Sonar Other SC-30 NMEA 2000 IF-NMEASC NMEA 0183 Roll, Pitch IF-NMEASC INTERFACE UNIT 12-24 VDC Video Plotter Radar Autopilot Current Indicator Scanning Sonar Video Sounder ECDIS Current Indicator Scanning Sonar Other : Standard supply...
  • Page 9: Mounting

    MOUNTING Equipment List Name Type Interface Unit IF-NMEASC Installation CP20-03001 Materials Spare Parts SP20-01301 Mounting Procedure When choosing a mounting location for the unit, keep the following points in mind: • Select a location where shock and vibration are minimal.
  • Page 10: Wiring

    WIRING Open the IF unit with your hands, detach the shield cover and connect external equipment, refer- ring to the illustration below and the interconnection diagram. Cables are mainly connected to the unit with WAGO connectors. See the instructions below for how to attach wiring to the connectors. The opener for the WAGO connectors is attached to the inside of the inner cover.
  • Page 11 S = 0.75 mm φ = 1.11 mm Data transmission cable supplied by FURUNO Do not connect this unit to NMEA 2000 bus. It is intended for one-to-one connection with the SC-30. Connection to an NMEA 2000 bus can result in network trouble and, in the worst case, fire.
  • Page 12: Adjustments

    Flashing: Valid NMEA 2000 data is input. ON: No valid NMEA 2000 data is input. OFF: CPU error, or no power. SENSOR2 Heading Pitch Roll Output Sentence Interval Output Sentence Interval Menu/ Enter Cancel LED state and equipment status CR33: Status LED for IF-NMEASC...
  • Page 13: Setting Up Nmea Ports

    Setting Up NMEA Ports Ports J4 and J5 output data in NMEA 0183 format. Select the data to output from those ports, along with baud rate and output interval. The default settings are as shown in the table below. Default settings for ports 2 and 3 Port no.
  • Page 14 3. ADJUSTMENTS 7. Push the [Menu/Cancel] button to light the Bps LED on the Port 2 line. Offset Port 2 Port 3 8. Push the [Enter] button. The Bps LED starts flashing and the current bps setting appears. Heading Offset Port 2 Sentence Port 3...
  • Page 15 13. Push the [+] or [-] button to select desired output interval, referring to the table below. Sentence Sentence number ATT, HVE VTG, GGA, ZDA RMC, ZDA ATT, HVE GGA, VTG, ZDA RMC, ZDA 14. Push the [Enter] button. The output interval LED stops flashing. 15.
  • Page 16: Heading, Pitch And Roll Offsets

    3. ADJUSTMENTS Heading, Pitch and Roll Offsets Turn on the IF unit and wait approx. three minutes for the satellite compass to settle. Then, check that heading, pitch and roll data are reasonable. If not, open the unit and enter appropriate off- set(s).
  • Page 17: Operation

    Normally, no operation is required except to power the unit (from the switchboard). The ST-BY LED on the cover is ON, OFF or flashing according to equipment state. Flashing: NMEA 2000 data is input ON: NMEA 2000 data is not input OFF: Power loss, blown fuse, operation error ST-BY LED IF-NMEASC INTERFACE UNIT ST-BY...
  • Page 18: Maintenance, Troubleshooting

    MAINTENANCE, TROUBLE- SHOOTING This chapter provides the information for keeping your unit in good working order. WARNING ELECTRICAL SHOCK HAZARD Do not open the equipment. Only qualified personnel should work inside the equipment. Preventive Maintenance Regular maintenance is important for good performance. Following the procedures in the table be- low will help maintain performance Preventive maintenance Item...
  • Page 19: Replacing The Fuse

    Replacing the Fuse The 2A fuse inside the unit protects it from overcurrent and equipment fault. If the power cannot be turned on, have a qualified technician check the fuse. If the fuse has blown, find out the cause before replacing it. If it blows again, contact your dealer for advice. Item Type Fuse...
  • Page 20: Self Test

    • The acceleration sensor is checked. The SENSOR2 LED lights if normal. When the test is finished, the nine LEDs below the display flash, and then the display shows "End.1". 4. Press the [Enter] button to return to self test 1. IF-NMEASC status SENSOR2 Self test 1 activated Pitch...
  • Page 21: Memory Clear

    3. After the memory is cleared, press the [Menu/Cancel] button to show the heading. 5. MAINTENANCE, TROUBLESHOOTING IF-NMEASC status SENSOR2 Roll Pitch Output Interval Output Interval Enter STATUS of IF-NMEASC SENSOR2 Heading Pitch Roll Output Sentence Interval Output Sentence Interval...
  • Page 22 5. MAINTENANCE, TROUBLESHOOTING This page is intentionally left blank.
  • Page 23: Specifications

    FURUNO SPECIFICATIONS OF INTERFACE UNIT INPUT PORT NMEA 2000*, for data I/O between FURUNO satellite compass SC-30 * NMEA 2000 is a registered trademark of the Nationa l Marine Electronics Association. OUTPUT PORT NMEA 0183: Two ports (HDT, HDG, HMD, ATT*, HVE*, VTG, GGA,...
  • Page 24 Jul.23'07 R.Esumi...
  • Page 25 12-24VDC) SUPPLY: (POWER DISPLAY MULTI-FUNCTION FG(SG) PWR_C PWR_H NET_L NET_H NET_C NET_S -060C,6m,φ8 NET_FG MJ-A10SPF0016 MJ-A10SPF XS2G-D5S7...
  • Page 26 This page is intentionally left blank.
  • Page 28 Nishinomiya, 662-8580, JAPAN Telephone : +81-(0)798-65-2111 : +81-(0)798-65-4200 Printed in Japan All rights reserved. Pub. No. OME-72651-A1 (DAMI ) IF-NMEASC The paper used in this manual is elemental chlorine free. ・FURUNO Authorized Distributor/Dealer A : DEC A1 : JAN . 28, 2008...

Table of Contents