https://appliancetechmanuals.com
2. Product Specifications
2-8. Operation theory of refrigeration cycle components
Capillary
1) Role: A device which makes low temperature and pressure refrigerant by reducing the pressure the
normal temperature / high pressure liquid refrigerant condensed from condenser, and supply it to
the evaporator.
A. To evaporate more lower temperature in case of evaporation.
B. It flows to the evaporator without back flowing to condenser, if compressor stops, and the difference of
pressure between high pressure and low pressure is small so it is easy to operate the compressor again.
2) Outline
A. Thickness : About 0.4~0.8mm
B. Length : It is changeable to low temperature and pressure (10->5ßΠ/ß≤) depends on the 2M
of thin and long copper pipe wall resistance.