6. Self Diagnosis & Trouble Shooting
6-20. Diagnosis for Sparkling system (Only for RF31FM*S*)
PROBLEM
Shooting Step 1
Nothing
coming
out when
Water coming out
pressing the
when pressing
Sparkling
the Water
Water
Dispenser Lever
Dispenser
Lever
Trouble
Trouble Shooting
Step 2
Function of Load
Condition Mode.
: It is displayed that
there is no detection for
both the Water Fill-Up
and the Water Empty
(R-10-ⓔ, R-10-ⓕ).
2. The Water Supply
Error is confirmed at
the Self Diagnostics
Mode.
: When pressing the
① and ⑤ buttons for
8 seconds at the
same time, it will
display 94E.
Possible Causes
1. Reset the CO2
Cylinder by pressing the
Sparkling Water button
(③) for 3 seconds
on the Display Panel and
reproduce the Sparkling
Water.
Defective 5-Way
2. When both the Water
Valve
Fill-Up and the Water
(No Water Supply)
Empty are not detected
(R-10-ⓔ,R-10-ⓕ) after
completing the
reproduction of the
Sparkling Water and
there is the Water Supply
Error, replace the Module.