5.
Use
to select the setting item, and press
Setting
Type
Threshold
.
This sets the limiter type.
1. Use
to select the type, and press
• Hard Knee: Only peaks that exceed the threshold are attenuated.
There is no effect below the threshold.
• Soft Knee: The limiter gradually affects the signal about 6 dB below
the threshold for a gentler effect.
This sets the level at which the limiter begins operating.
1. Use
to adjust the setting, and press
This can be set from −16 to −2 dBFS.
62
Explanation
.
.