5.
Use
to set how timecode is initialized, and press
Setting
Restart Time
RTC
When the F8n Pro starts, the value set by "Restart" is used to jam the
(→Restarting internal timecode with a specified
internal timecode.
value)
When the F8n Pro starts, its timecode is restored from the timecode
when the power was turned off and advanced by the elapsed time
using the "Date/Time (RTC)" setting
(Date/Time
(RTC))).
Since RTC is less precise than internal timecode, discrepancies will
occur.