Installing the CSVEQ 100 D

The CSVEQ 100 D is a wall-mounted product and can be
mounted into an electrical wall box. This section includes site
preparation, wall box installation, and the mounting of the line
driver in the wall box.
N

Preparing the site and installing the wall box

Choose a location that allows cable runs without interference.
Allow enough depth for both the wall box and the cables. You
may need to install the cables into the wall or conduits before
installing the line driver.
The line driver can be installed in a standard one-gang electrical
wall box. The installation must conform to national and local
electrical codes. A dimensional drawing and a cutout template
of the line driver are provided in appendix B of this manual.
N
1.
2.
3.
4.
5.
The line driver must be installed into an Underwriters
Laboratories (UL) approved electrical wall box. The
box is not included with the line driver; the installer is
responsible for obtaining and installing the box.
The cutout template shown in appendix B is not full size.
Pay attention to the measurements shown on the template.
Mark the guidelines for the opening on the wall.
• If the line driver is to be installed in a wall box, place
the box against the installation surface and draw a line
on it around the outside of the box.
• If the line driver is to be installed without a wall box
(fastening it directly to the wall), measure and mark
the surface for the cutout area indicated in the cutout
template.
Cut out the material from the marked area.
Check the opening size by inserting the wall box (if used)
or the line driver (if no box is used) into the opening. The
box and line driver should fit easily into the opening.
Enlarge or smooth the edges of the opening if needed.
Feed cables through the wall box punch-out holes, and
secure them with cable clamps to provide strain relief.
Insert the wall box into the opening, and attach it to the
wall or stud using nails or screws. The front edge should
be flush with the outer wall surface. See the following
illustration.
CSVEQ 100 D • Installation