Alarms And Warnings - Pentair STA-RITE INTELLIFLO3 VSF Installation And Maintenance Manual

Variable speed and flow pumps
Hide thumbs Also See for STA-RITE INTELLIFLO3 VSF:
Table of Contents

Advertisement

22

Alarms and Warnings

When an alarm is triggered the drive's ON/STOP LED will blink RED and a fault code will display. The pump will stop
until the alarm is resolved.
When a Warning is triggered the drive's ON/STOP LED will blink GREEN/YELLOW and a fault coded will display.
Depending on your particular setup, fault codes will display on one or more of the user interfaces:
Pentair Home App
Automation System Interface
Optional Touchscreen Controller (Almond - P/N 356159z, Black - P/N 356348z)
ALARM /
DESCRIPTION
WARNING
Weak Wi-Fi
Weak Wifi connection
Connection
detected.
Offline
The pump is offline.
Priming Failure
The pump has reported a
Priming Failure Alarm.
Overheat
The pump has reported an
Overheat Condition.
Over Current
The pump has reported an
Over Current Condition.
Over Voltage
The pump has reported an
Over Voltage Alarm.
Under Voltage
The pump has reported an
Under Voltage Alarm.
Speed Limit
The pump has reported a
Speed Limit Warning.
Pressure Limit
The pump has reported a
Pressure Limit Warning.
Flow Limit
The pump has reported a
Flow Limit Warning.
Internal Fault
The pump has an internal
error.
Drive is Derating
The pump is slowing down
(Warning)
to prevent the drive from
overheating.
Derating Alarm -
The pump has stopped
Exceeded & Cut
to prevent the drive from
Off
overheating.
Thermal Mode
The pump operating in
Thermal Mode.
INTELLIFLO3™ VSF / INTELLIPRO3™ VSF Variable Speed and Flow Pump Installation and Maintenance Guide
Pump antenna may be obstructed or too far away from your router. The antenna wire
can be extended.
Refer to Relocating the WiFi Antenna on page 18.
The Pentair cloud cannot connect to your pump.
This could be caused by a power outage at the pump or router, or a loss of WiFi
signal to the pump.
Priming failure can be caused by lack of water in the volute strainer basket.
The pump motor has detected an abnormally high internal temperature. This can be
caused by a blockage of the cooling fan inlet or outlet, or by excessively high ambient
air temperature.
The pump will attempt to protect itself by reducing the motor speed to give the motor
and drive a chance to cool down.
Load has increased on the motor; due to debris, part interference, temperature
issues, age of parts, or supplied voltage.
Refer to Disassembly on page 16 and inspect the rotating parts of the pump for
blockages or debris buildup.
Supplied voltage is outside of the proper range. When voltage returns to the normal
the alert will clear and the pump will resume operation.
Supplied voltage is outside of the proper range. When voltage returns to the normal
the alert will clear and the pump will resume operation.
The pump is operating at the programmed maximum speed in order to achieve the
desired speed/flow.
Refer to Limits Parameters on page 11 for instructions on adjusting the Speed
Limit.
If this alert displays and the Speed Limit is already set to 100%, then the pump may
not be capable of achieving the desired flow rate.
The pump is operating at the programmed maximum system pressure.
The pump monitors Total Dynamic Head, and not outlet pressure, so it may differ from
the reading on the filter gauge.
Refer to Limits Parameters on page 11 for instructions on adjusting the pump
Pressure Limit.
The pump is operating at the programmed maximum flow rate.
Refer to Limits Parameters on page 11 for instructions on adjusting the pump Flow
Limit.
This alert can be caused by a few different types of internal hardware or software
errors in the drive.
Disconnect power to the pump and reconnect after one minute. If the alert remains,
contact a qualified pool professional.
This alert usually accompanies an Overheat or Over Current alert.
It is intended to note that the pump will continue to operate at a reduced speed as
long as possible.
After the drive has cooled enough it will automatically resume normal operation.
The motor and drive are not able to reduce speed enough to protect themselves.
The motor will stop and Pentair Home will display this alarm.
When the drive has cooled enough, it will automatically resume operation and attempt
to run the requested program.
The pump is operating in Thermal mode. Thermal Mode is controlled by the drive's
internal temperature, not water temperature.
This is intended to keep motor components from freezing, but should not be
solely relied on for full filtration system freeze protection.
DEFINITION

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sta-rite intellipro3 vsfIntelliflo3 vsf

Table of Contents