Troubleshooting; Drive Led Indicators; Troubleshooting Chart - Pentair STA-RITE INTELLIFLO3 VSF Installation And Maintenance Manual

Variable speed and flow pumps
Hide thumbs Also See for STA-RITE INTELLIFLO3 VSF:
Table of Contents

Advertisement

Always disconnect power to the pump at the circuit breaker and relieve pressure in the filtration system before servicing the pump. Failure
to do so could result in death or serious injury to serviceman, pool users or others due to electric shock. Do NOT attempt to adjust or
service without consulting your dealer or a qualified pool technician. Read the entire Installation and Maintenance Guide before attempting
to use, service, or adjust the pool filtering system or heater.

Drive LED Indicators

Each button on the drive;
CONNECT, ON/STOP and
QUICK CLEAN features an
LED indicator.
Refer to the table to the right
for a list of LED behaviors
and what they are indicating.
= Solid LED
= Blinking LED
= Pulsing LED

Troubleshooting Chart

PROBLEM
Connection Issue -
Pump is Offline Alert
LED
Green
Blue
CONNECT
Yellow
Magenta/Pink
Green
ON/STOP
Red
Green/Yellow
Yellow
POSSIBLE CAUSE
Pump is not receiving power
Home internet service is out or
inaccessible
Intermittent WiFi or network
connection
connectivity issues
Bluetooth
®
- Troubleshooting Continues on the Next Page -
INTELLIFLO3™ VSF / INTELLIPRO3™ VSF Variable Speed and Flow Pump Installation and Maintenance Guide

TROUBLESHOOTING

BEHAVIOR
Pulsing
Attempting to establish WiFi connection
Solid
Active WiFi connection
Blinking
Attempting to establish a Bluetooth
Solid
Active Bluetooth
Pulsing
Pump requires provisioning
Blinking
Pump update in progress
Solid
Automated control is active
Pulsing
Connected to automation and in service mode
Solid
Pump running
Blinking
Priming cycle
Pulsing
Pump in Thermal Mode
Solid
Pump disabled
Blinking
Alarm detected
Blinking
Warning detected
Solid
Pump is idle
CORRECTIVE ACTION
Ensure the pump is receiving power.
If the pump is receiving power, the ON/STOP button will
illuminate.
Confirm that the home router is active and connected to
the internet.
1.
Restart the home router. This can clear up many
typical home networking issues.
2.
Cycle power to the pump.
Disconnect power to the pump at the main breaker,
Wait for 1 minute and reconnect power.
3.
Check the signal strength in WiFi Settings of the
Pentair Home App.
If the signal strength is insufficient, refer to the Poor
WiFi Signal section of this troubleshooting chart.
1.
Stand closer to the pump when operating via
Bluetooth
.
®
2.
Restart the Pentair Home app.
3.
Adjust the pump antenna.
4.
Ensure smartphone permissions are given to the
pump.
INDICATES
connection
®
connection
®
19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sta-rite intellipro3 vsfIntelliflo3 vsf

Table of Contents