Device Settings - Pentair STA-RITE INTELLIFLO3 VSF Installation And Maintenance Manual

Variable speed and flow pumps
Hide thumbs Also See for STA-RITE INTELLIFLO3 VSF:
Table of Contents

Advertisement

Device Settings

Pump Dashboard ˃ Device Settings
Device Settings can be accessed by pressing the Device
Settings gear icon (
) in the bottom-right of the Pump
Dashboard.
Tap EDIT to enter any of the menus described below:
1− Product Overview: View general information about
your pump such as device nickname, address or
software version.
2− Screen Orientation: Choose how the screen is
displayed.
The screen can be shifted to different orientations to
best fit a specific install.
3− WiFi: View WiFi network information and signal
strength.
4− Brightness and Delays: View and edit screen brightness, dimming and timeout settings.
5- Relays: View and edit your current pump relay device settings.
Refer to Relay Settings, page 10.
Note: This option will only display if the optional Relay Control Board (P/N 356365z) is installed.
6- Priming Parameters: View and edit your pump's priming settings.
Refer to Priming Parameters, page 10.
7- Limits Parameters: View and edit your pump's speed, flow and pressure limits.
Refer to Limits Parameters, page 11.
8- Thermal Mode: View and edit the your pump's Thermal Mode temperature set point and speed/flow settings.
9- Automation Configuration: View and edit the pump address associated with your automation system.
The pump address entered on this screen must match the address in the automation system. If
addresses do not match, the pump can not communicate with an automation system.
10- External Control Programs: View and edit the four programs that can be triggered by an external input
signal when using the optional Relay Control Board (P/N 356365z).
Refer to Relay Control Board Digital Inputs, page 5 for more information.
Note: If multiple external input triggers are received, programs will follow the following priority:
PROGRAM 4 > 3 > 2 > 1.
Note: If the pump has been stopped via the ON/STOP button (ON/STOP LED is solid red), ON/STOP must be
pressed again before the pump will operate.
11- Ramping Speed: Set how quickly your pump will ramp up or down on startup or when changing speeds/flows.
Ramping Speed can be set to FAST, MEDIUM or SLOW.
12- Languages: Select the language you wish your touchscreen controller to display.
INTELLIFLO3™ VSF / INTELLIPRO3™ VSF Variable Speed and Flow Pump Installation and Maintenance Guide
"DEVICE SETTINGS" SCREEN
9