Upper Heater Assembly - GE Advantium 120 Technical Service Manual

Hide thumbs Also See for Advantium 120:
Table of Contents

Advertisement

Upper Heater Assembly

The halogen heater has an approximate resistance
value of 1.8 to 3.7 Ω. It is connected using a white
wire harness.
The ceramic heater has an approximate resistance
value of 15 to 25 Ω. It is connected using a yellow
wire harness.
To remove the upper heater assembly:
Caution: Mark each of the wire harnesses
before disconnecting. The connectors could be
interchanged, causing an adverse effect in cooking
performance.
1.
Remove the oven from cabinet or wall opening
and remove the outer cover. (See
.)
Partial Removal
2.
Disconnect the heater assembly wire harnesses
and pull them through the wire guide.
3.
Disconnect wires from the upper heater TCO.
4.
Remove the 2 Phillips-head screws, wire retainer,
and the heater shield from the heater assembly.
5.
Straighten the 4 folded lock tabs.
6.
Remove the 8 Phillips-head screws that attach
the heater cover. Lift off the cover.
Oven Removal /
7.
Remove the 3 Phillips-head screws that attach
the heater assembly to the oven chassis.
8.
Carefully lift the heater assembly from the oven
chassis.
– 34 –
Lock Tabs

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scb 1000Scb 1001Zsc 1000Zsc 1001

Table of Contents