GE Advantium 120 Technical Service Manual page 27

Hide thumbs Also See for Advantium 120:
Table of Contents

Advertisement

To remove the control panel bracket:
1.
Remove the control panel. (See
.)
Assembly
2.
Disconnect wire harnesses from the relay board
at location CN3 and from the power board at
location CN4.
3.
Peel back the foam tape and release the wire
harness to CN4 from the wire retainer.
4.
Remove the 4 Phillips-head screws (2 on each
side) from the control panel bracket.
5.
Slide the control panel bracket to the right then
lift the control panel bracket from the control
panel.
6.
Guide the disconnected harnesses through the
wire entry hole in the control panel bracket.
Wire Retainer
Wire Entry Hole
Foam Tape
To remove the control board:
1.
Control Panel
2.
3.
4.
To remove the display board:
The display board is attached to the control panel
by 2 Phillips-head screws and positioned by 2 pins.
The display board connects to the control board
with a 20-pin wire harness. To access the display
board it is necessary to remove the control panel
bracket. (See
– 27 –
Remove the control panel bracket. (See
.)
Panel Assembly
Disconnect the 20-pin harness connector from
the display board.
Disconnect the wire harnesses from the selector
board at locations CN9 and CN13.
Remove the 4 Phillips-head screws that hold the
control board to the control panel.
Control Panel Assembly
20-Pin Wire Harness
Control
.)
(Continued Next Page)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scb 1000Scb 1001Zsc 1000Zsc 1001

Table of Contents