Convection Heater Element
The convection heater assembly is held in place
by two 7-mm hex-nuts and 4 Phillips-head screws
The convection heater element has an approximate
resistance value of 9.5 Ω. Two Phillips-head screws
connect the power wires to the element terminals.
The convection heater
element is held in place
by 4 Phillips-head
screws. (Three screws on
the front, and 1 screw
on the end.)
End View of Element
– 36 –
Convection Fan Motor
The convection fan motor wire leads have locking
tabs that must be depressed to be disconnected.
To remove each wire from the fan motor, depress
the clip using a small blade screwdriver and pull the
wire off the terminal as shown.
ELECTRICAL TERMINAL
RELEASE/LOCKING TAB
The outer convection fan must be removed before
removing the motor. The outer convection fan is
held in place by a 7-mm nut, lockwasher, spacer
and fl at washer.
Front View of Outer Convection Fan
The convection fan motor is held in place by 3
Phillips-head screws .
Rear View of Convection Fan
Convection Fan Motor