Door Assembly - GE Advantium 120 Technical Service Manual

Hide thumbs Also See for Advantium 120:
Table of Contents

Advertisement

Door Assembly

WARNING: A microwave leakage test must be
performed any time a door is removed, replaced, or
adjusted for any reason. (See
.)
Information
Door Removal
Caution: Do not close the door beyond the door
removal position. Damage to the inner door panel
will occur.
To remove the door, open the door fully and insert a
door removal tool (Part # WB01X10318) in each door
hinge opening. The door can then be slowly closed
a few inches to the door-removal position and lifted
from the oven.
Tool
Door Hinge Opening
Door-Removal Position
Diagnostic and Service
Tool
– 24 –
To disassemble the door:
1.
Remove the 4 screws from the glass mount.
2.
Remove the choke cover.
3.
Remove the 4 screws from the door frame, and
remove door frame from the glass supporter.
4.
Remove the 4 screws from the glass supporter,
and remove the door handle and vent trim from
the glass supporter.
SCB1000K and SCB1001K
Latch
Latch
Spring
Glass
Supporter
Door
Handle
Glass Mount
Door Glass
ZSC1000K and ZSC1001K
Latch
Latch
Spring
Door
Handle
Door Glass
Choke Cover
Latch
Spring
Door
Frame
Door Deco
Choke Cover
Latch
Spring
Door
Frame
Door Panel