Humidity Limits:
EMI Effect:
Surge Protection:
Vibration Effect:
5.4 PHYSICAL SPECIFICATIONS
Fill Media:
Electronics Housing:
Electrical Connections:
2808B
Specified
with
Transmitter
housing cover installed.
15-95% RH to 140 °F (60 °C)
15-50% RH to 185 °F (85 °C)
+1% of URL @ 10 V/M, 20 MHz to 500 MHz
Meets /SAMA PMC-33-1C with Transmitter
cover in place and all wiring contained in
grounded conduit.
Bipolar, differential surge
1000 watts for 1 ms (without digital
indicator option)
May
be
used
with
protector for additional protection (for non-
hazardous,
non-approved
only).
Less than +0.1% of URL for 10 to 500 Hz at
1 g on any axis. Meets SAMA PMC-31-1
DC 200 Silicone
Low copper aluminum, epoxy finish, NEMA
4X rating
1/2 NPT conduit connection with internal
field wiring terminals.
electronic
purchased
surge
installations