Collector Supports With Fixed Angle Of Inclination - Viessmann Vitosol 200-T Installation Instructions Manual

Table of Contents

Advertisement

Installation on collector supports
h
α
z
z
sin (180°– (α+β))
=
h
sin β
2241 mm · sin (180° – 61.5°)
z =
sin 16.5°
z =
6934 mm
Fig. 64
z Collector row spacing
h Collector height
Installation information
The collector supports for angles of inclination
45° and 60° are pre-assembled with screws, wash-
ers, nuts and clamping brackets.
Observe the maximum load and distance from the
edge of the roof for the on-site substructure to
DIN 1055.
Remove any gravel or similar from the installation
area. Cover the area with protective mats and posi-
tion the support slabs on top of the mats (see follow-
ing diagrams).

Collector supports with fixed angle of inclination

Collector supports for angles of inclination
and 60° are pre-assembled with screws, washers, nuts
and clamping brackets.
(cont.)
h
α
β
25°,
α
25°, 45°
α
Collector angle of inclination
α
Angle of the sun
β
Align the collector array to face due south.
Calculation of ballast and maximum load on the sub-
structure according to DIN 1055-4: 2005-03 and DIN
1055-5: 2005-07.
The Viessmann "SOLSTAT" calculation program is
available at www.viessmann.com to assist with cal-
culations.
For calculating dimension z, see page 50.
51

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vitosol 300-tSp2aSp3b

Table of Contents