Collector Supports With Fixed Angle Of Inclination - Viessmann VITOSOL 200-T Installation Instructions Manual

Vacuum tube collectors based on the heat pipe principle sp2a sp3b
Table of Contents

Advertisement

Elevated installation
Installation information
■ Observe the maximum load and dis-
tance from the edge of the roof, sub-
ject to the on-site substructure, in com-
pliance with DIN 1055.
■ Remove any gravel or similar from the
installation area. Cover the area with
protective building mats and position
support slabs A and B on top of these
mats (see following illustrations).
■ Where possible, face the collector
array due south.

Collector supports with fixed angle of inclination

Collector supports for angles of inclina-
tion α 25, 45 and 60° are pre-assembled
with screws, washers, nuts and clamping
brackets.
60
(cont.)
■ Calculation of ballast and maximum
load on the substructure according to
DIN 1055-4: 2005-03 and DIN 1055-5:
2005-07.
Per collector, 2 support slabs A and 2
support slabs B are required.
The Viessmann "SOLSTAT" calcula-
tion program is available at
www.viessmann.com to assist with
calculations.
■ For calculating dimension z, see
page 59.