Electrical Connection

The cooker must be installed by a qualified electrician, in
accordance with all relevant British Standards/Codes of
Practice (in particular BS 7671), or with the relevant national
and local regulations.
WARNING: THE APPLIANCE MUST BE EARTHED.
n
Note: The cooker must be connected to the correct electrical
supply as stated on the voltage label on the cooker, through
a suitable cooker control unit incorporating a double-pole
switch, having a contact separation of at least 3 mm in all
poles.
The cooker MUST not be connected to an ordinary
n
domestic power point.
Access to the mains terminal is gained by removing the
electrical terminal cover box on the back panel. Connect the
mains cable to the correct terminals for your electrical supply
type (Fig. 8.8 and Fig. 8.9). Check that the links are correctly
fitted and that the terminal screws are tight. Secure the mains
cable using the cable clamp.

Final Checks

Hob Check
Check each cooking zone in turn. Be sure to use pans of the
correct size and material.
Grill Check
Turn on the grill control and check that the grill heats up.
Oven Check
Set the clock as described earlier, and then turn on the ovens.
Check the oven fans start to turn and that the ovens heat up.
Fitting the 2-piece Plinth
Fit the inner plinth to the bottom front of the cooker using
the 4 screws provided (Fig. 8.10).
Fit the outer plinth (2 screws, 1 each end) to the inner plinth.
The height of the outer plinth can be adjusted by sliding it up
or down via the slotted hole (Fig. 8.11).
Customer Care
Installer: Please complete your details in this guide, inform
the user how to operate the cooker and hand over the
instructions.
Thank you.
INSTALLATION
Check the appliance is electrically safe when you have finished.
Current Operated Earth Leakage Breakers
The combined use of your cooker and other domestic
appliances may cause nuisance tripping, so we recommend
that the cooker is protected on an individual RCD (Residual
Current Device) or RCBO (Residual Current Breaker with
IF IN DOUBT, PLEASE CONSULT A SUITABLY QUALIFIED
L
N
10 mm² max
ArtNo.130-0010 Electrical connections single-phase
230 V ac 50 Hz
L1
N
L3
L2
6 mm² max
3N ac
230/400 V 50 Hz
ArtNo.350-0010 - Fitting the plinth 1 (Kitchener)
ArtNo.350-0011 - Fitting the plinth 2 (Kitchener)
Inner plinth
27
Overload).
ELECTRICIAN.
10 mm² max
Outer plinth
Outer plinth xing screw
Fig. 8.8
6 mm² max
Fig. 8.9
6 mm² max
Fig. 8.10
Fig. 8.11

Advertisement

Table of Contents
loading

Table of Contents