Understanding Shortcuts

Use the shortcuts in this section to reduce repetition and
provide speedy instructions to control panel
programming.
Main Menu is the first level in the system. For all system
programming, <PROG/0> is be your Main Menu
option. The first number in the shortcut is "0."
The second level in your system provides eight options:
1- PROG TIME
2- SECURITY
3- ROG SYSTEM
4 -PROG INPUTS,
5- PROG OUTPUTS,
6- PROG ACCOUNTS
7- PROG FORMATS
8- HISTORY DEFAULTS
The second number in the shortcut enters the Level 2
option and brings you to Level 3. When the D7039
MUX Expander is installed, a ninth option,
PROGRAM MUX, appears. Level 3 provides the third
set of options that branch from Level 2 (Figure 19). The
third number in the shortcut represents the option
selected in Level 3.
The example in Figure 19 shows the shortcut to TEST
FREQ and TEST TIME. The Programming Menu Tree
(Figure 18 and Figure 19) shows that you access TEST
TIME and TEST FREQ by selecting the following
options sequentially from Level 1 to Level 3: PROG/0
> PROG TIME > AUTO TEST. The shortcut is a list of
the buttons you press to access the fourth level option
you want. When you enter the shortcut, follow the
procedure for the specific function you are
programming.
6.6

Remote Programming

The system remains operational during remote
programming allowing new alarms to terminate the
remote programming session and report normally.
Using the keypads to perform other functions during
remote programming, such as tests and disables, can
cause remote programming to disconnect or other
unexpected operations. Do not download programming
changes that can cause alarms. The session disconnects
when the alarm occurs, before the session completes. To
indicate the system is in a special operating mode with
user input inhibited, but alarm monitoring continuing
SYSTEM TROUBLE, RMT PRG ACTIVE appears
during remote programming. Sounders do not activate
during this mode, but other outputs programmed for
Zone 62, general system trouble, activate.
Bosch | 7/05 | 31499J
D7024 | Operation and Installation Guide | 6.0 Programming
Figure 19: Programming Shortcut
Shortcut = 012
LEVEL 1
LEVEL 2
(Main Menu)
1- PROG TIME
5
PROG/0
4
6
1 – Press [0] to select PROG at the Main Menu
scrolling at the SYSTEM NORMAL display.
2 – Press [1] to select PROG TIME at Sub-Level 2.
3 – Press [2] to select AUTO TEST at Sub-Level 3.
4 – First number in the shortcut
5 – Password
6 – Second number in the shortcut
7 – Third number in the shortcut
8 – Fourth number in the shortcut
1
Refer to Section 5.2 Using the System on page 22.Enter
PIN if prompted.
2
Follow the procedure. This example is for TEST TIME and
TEST FREQNCY. Refer to Section 7. 1 .2 Automatic Test
on page 36.
Trouble conditions occurring during a remote
programming session do not annunciate at the control
panel until the session ends. These conditions are
available in the remote programmer diagnostic displays
during the session. Alarm conditions terminate remote
programming and appear immediately.
When remote programming is disables, it can still
connect to the control panel for diagnostics and view the
current programming, with the exception of PINs). To
change programming, you must enable remote
programming. Use the following programming items to
enable remote programming:
0-3-7 Remote Programming refer to Section 7.3.5
Remote Programming on page 40).
0-6-1 Computer Phone (refer to Section 7.6.1 Phone
Numbers on page 48).
0-6-1 Account Number 1 (refer to Section 7.6.2 Phone
Control on page 50, Account Numbers).
0-6-2 Dialing Type (refer to Section 7.6.2 Phone
Control on page 50, Dialing Type).
0-6-4 Ring Count (refer to Section 7.6.4 Ring Count
on page 51).
0-6-6 Machine Bypass (refer to Section 7.6.6 Machine
Bypass on page 52).
You need an access code with maximum authority (1) to
initiate remote programming from the control panel.
2
1
3
LEVEL 3
LEVEL 4
1- SYSTEM
1- TEST TIME
2- AUTO TEST
2- TEST FREQNCY
7
8
1
2