Rocker Switch; 24V Relay; Drain Valve Position Sensor - Vulcan-Hart CEF40 Service Manual

Table of Contents

Advertisement

CEF40/75 FRYER - REMOVAL AND REPLACEMENT OF PARTS
5.
Remove screws, stand-offs, and CEF controller
board.
6.
Reverse procedure to install.

ROCKER SWITCH

electrical power to the machine and
follow lockout / tagout procedures.
NOTE: There are three rocker switches.
Replacement procedure is same for all.
1.
Remove CONTROL BOX ASSEMBLY.
2.
Disconnect rocker switch from harness.
3.
Remove rocker switch (Fig. 10) from control box
assembly.
Fig. 10
4.
Reverse procedure to install.

24V RELAY

electrical power to the machine and
follow lockout / tagout procedures.
1.
Remove CONTROL BOX ASSEMBLY.
2.
Disconnect wires from relay (Fig. 11).
Disconnect the
Disconnect the
Page 7 of 25
Pin
1
2
3
4
5
6
7
8
Fig. 11
3.
Remove nuts and relay.
4.
Reverse procedure to install.

DRAIN VALVE POSITION SENSOR

electrical power to the machine and
follow lockout / tagout procedures.
1.
Remove BULLNOSE .
2.
Rotate and lift to remove fryer door plate (Fig.
12).
Wire
NC
NC
63
NC
65
NC
56
42
Disconnect the
F45657 (0517)

Advertisement