Troubleshooting; 疑难解答 - Kohler C3-400 Homeowner's Manual

Smart seat
Hide thumbs Also See for C3-400:
Table of Contents

Advertisement

TROUBLESHOOTING / 疑难解答
This troubleshooting guide is for general aid only. Kohler Authorized Service
Representatives can resolve any related electrical problems. For warranty
service, contact your dealer or wholesale distributor.
General Functions
Phenomenon
1. The unit does
not work.
2.Bidet seat is
loose.
3. Water does not
spray out of the
wand.
4. No water flow.
Kohler Co.
Possible Causes
A. power failure occurred.
B. The power cord is
disconnected.
C. Ground-Fault Circuit
Interrupt (GFCI) may be
tripped.
D. The seat fails to detect
user.
E. Thermal protector auto
protection is activated.
F. None of the above
solutions take effect.
A. Screws and nuts are
loose.
A. The seat fails to detect
user.
B. Water supply failure.
C. Filter is clogged.
D. None of the above
solutions take effect.
A. The water supply valve is
turned off.
B. The seat-on sensor fails to
detect the user.
Recommended Solution
A. Wait until the power is
restored.
B. Insert the power cord into
a power outlet.
C. Press the re-set button on
the plug.
D. Contact seat sensing
area.
E. Place product at ambient
temperature for some time.
F. Contact a Kohler Service
Representative.
A. Tighten the screws
and nuts according to the
Installation Guide.
A. Contact seat sensing
area.
B. Power off, remove water
supply fault and power on
again.
C. Refer to "CLEAN FILTER"
section.
D. Contact a Kohler Service
Representative.
A. Open the water supply
valve.
B.Check how to activate the
seat in the "INSTALLATION
INSPECTION" section of the
"Installation Guide."
21
1349982-T01-A

Advertisement

Table of Contents
loading

This manual is also suitable for:

K-22445tw-0K-26134k-0K-26134tw-0

Table of Contents