Zero-Clearance (Metal) Fireplace Requirements - Lopi Evergreen NexGen-Fyre Insert Manual

Table of Contents

Advertisement

12
Fireplace Insert Installation

Zero-Clearance (Metal) Fireplace Requirements

Must be manufactured by one of the following manufacturers:
• Marco
• Majestic
• Heat N Glo
Entire fireplace, including chimney, must meet local building requirements
Chimney height: 15' minimum; 33' maximum.
The damper ("A") and grate ("B") must be removed
(see illustration to the right). The smoke shelf ("C"),
internal baffles ("D"), screen ("E"), and metal or
glass doors ("F") may be removed (if applicable).
The masonry lining ("G"), insulation ("H"), and any
structured rigid frame members (metal sides, floor,
door frame, face of the fireplace, etc. – "I") may not
be removed or altered.
The chimney on the ZC fireplace must be listed per UL 127 or ULC 610-M87 for all installations. Any
thermal protection component of the fireplace or chimney must remain in place. The fireplace and
chimney must be inspected prior to installation. A NFPA 211 Level II inspection is recommended.
Repairs must be made prior to insert installation. The base of the fireplace must be structurally sound
and able to support the weight of the insert.
The stainless steel liner must be 6" in diameter and extend the full height of the chimney (also called
a positive connection or full re-line). This liner must meet type HT (2100°F) requirements per UL
1777 (USA) or ULC S635 with "0" clearance to masonry (Canada). The liner must be attached to the
insert flue collar and to the top of the existing chimney.
We recommend using the listed Travis ZC Liner Kit from Duravent (SKU 98900046, 47, or 48). If you
do not use this kit, you must use the original ZC chimney cap.
The liner support and cap at the top of the chimney must not reduce airflow for the existing air-cooled
chimney system. The Travis ZC Liner Kit includes a cap that meets this provision.
To prevent air from passing up the ZC fireplace chimney (the gap between the liner and chimney) we
recommend sealing the area near the damper. Use non-combustible material to seal this area (non-
backed fiberglass insulation or kaowool).
The convection air channel on the fireplace must not be blocked. Do not block any louvers, grills, or
air passages on the front of the fireplace.
Entire fireplace, including chimney, must meet local building requirements. Permits may be required
for installation. Final approval is contingent upon the authority having local jurisdiction. Inform your
insurance agent of this fireplace insert.
Factory-Built (Z.C.) Fireplace hearth floor protection must be 3/8" (9.5mm) minimum non-combustible
material or equivalent, extending 16" in front of insert and 8" to both sides for US installations and 18"
(458mm) in front of insert and 8" (204mm) to both sides in Canada.
© Travis Industries
• Heatilator
• Preway
• Lennox
• Martin
• Monesson
11/5/2021 - 1560
(for qualified installers only)
• Tempco
• Superior
H
C
F
E
A
D
I
IDB1131
B
G
Evergreen Insert