Performance Monitoring
PURPOSE
This procedure provides instructions for monitoring performance of the 1677 SONET Link.
GENERAL
Individual performance monitoring (PM) registers are used to store performance information that
can be retrieved under command. This data is stored on 15-minute increments for up to eight hours
(or 32 consecutive 15-minute periods), and daily for the current and previous 24-hour period.
Performance information can be retrieved on demand, or through scheduled PM reports.
For information on TL1 command syntax, refer to the 1677 SONET Link Commands and Messages
manual (PN 3EM13852AF).
STEP
PROCEDURE
Select action.
1
Retrieve PM Data
Enter
2
or
RTRV-PM-x::[AID]:::[MONTYPE],[MONLEV],,,[TMPER],[MONDAT],[MONTM];
where:
x=Facility Type (EC1, GIGE, OC3, OC12, OC48, OC192, OFA, STS1, STS3C, STS12C,
STS48C, T1, T3, VT1).
AID=Access Identifier of the facility, or is omitted for all facilities of that type.
MONTYPE=Threshold (monitored parameter) name, or is omitted for all thresholds.
Performance Monitoring
To retrieve PM data, go to step 2.
To initialize PM registers, go to step 5.
To retrieve threshold values, go to step 7.
To set thresholds, go to step 10.
To retrieve PM mode, go to step 12.
To set PM mode, go to step 15.
To retrieve PM reporting schedule, go to step 17.
To schedule PM reporting, go to step 19.
To inhibit PM reporting, go to step 21.
To allow PM reporting, go to step 23.
To end this procedure, go to step 25.
RTRV-PM-ALL:::::[MONTYPE],[MONLEV],,,[TMPER],[MONDAT],[MONTM];
RTL-101