3EM13853AF
Issue 01, September 2007
TAP-130

INHSWPR Alarm

PURPOSE
This procedure provides instructions to clear an INHSWPR alarm against a DS3, ECC, TMUX, or
VSC card.
GENERAL
INHSWPR indicates protection switching (automatic and manual) from working to protect is
inhibited.
For information on TL1 command syntax, refer to the 1677 SONET Link Commands and Messages
manual (PN 3EM13852AF).
STEP
PROCEDURE
Enter
1
Note AID of card with INHSWPR alarm.
2
Enter
3
where:
AID=Equipment Access Identifier of card with INHSWPR
Did output return COMPLD or DENY?
4
Enter
5
Did INHSWPR alarm clear for card?
6
Contact next level of technical support for assistance.
7
8
STOP. This procedure is complete.
INHSWPR Alarm
and
RTRV-ALM-ALL;
RTRV-COND-ALL;
ALW-SWTOPROTN-EQPT::AID;
If COMPLD, go to step 5.
If DENY, go to step 7.
and
RTRV-ALM-ALL;
RTRV-COND-ALL;
If yes, go to step 8.
If no, go to step 7.
to retrieve all alarms and conditions.
for card with INHSWPR.
to retrieve all alarms and conditions.
TAP-130