Error - Alcatel-Lucent 1677 SONET Maintenance And Trouble Clearing

Hide thumbs Also See for 1677 SONET:
Table of Contents

Advertisement

3EM13853AF
Issue 01, September 2007
TAP-149

ERROR

PURPOSE
This procedure provides instructions to clear an ERROR equipment alarm or event.
GENERAL
Refer to the 1677 SONET Link Address and Location Guide (PN 3EM13854AD) to determine facility
and module location and address.
STEP
PROCEDURE
ERROR indicates SET-SYNCN has been executed and AUTOREFSW has been set to
1
switching inhibited (INH).
Does AUTOREFSW need to be set to switching allowed (ALW)?
Enter
2
Did output return a COMPLD or DENY?
3
Enter
4
Observe output. Did ERROR alarm clear?
5
Contact next level of technical support for assistance.
6
7
STOP. This procedure is complete.
ERROR
If yes, go to step 2.
If no, go to step 7.
SET-SYNCN::::::AUTOREFSW=ALW
If COMPLD, go to step 4.
If DENY, go to step 6.
and
RTRV-ALM-ALL;
RTRV-COND-ALL;
If yes, go to step 7.
If no, go to step 6.
;
to retrieve all alarms and conditions.