PURPOSE
This procedure provides instructions to clear a FRCDWKSWPR or MANWKSWPR alarm on a DS3,
ECC, TMUX, or VSC module.
GENERAL
FRCDWKSWPR indicates a forced switch of service from working to protection equipment.
MANWKSWPR indicates a manual switch of service from working to protection equipment.
For information on TL1 command syntax, refer to the 1677 SONET Link Commands and Messages
manual (PN 3EM13852AF).
STEP
PROCEDURE
Module under protection must be manually switched back to working to clear
1
FRCDWKSWPR or MANWKSWPR alarm.
Is module to be switched back to working at this time?
Enter
2
Are there other alarms on module with FRCDWKSWPR or MANWKSWPR?
3
Resolve other alarms. Refer to IXL-101.
4
Enter
5
Is module state IS,STBYH or OOS-MA?
6
Is module to be logically restored into service?
7
FRCDWKSWPR or MANWKSWPR Alarm
If yes, go to step 2.
If no, go to step 15.
and
RTRV-ALM-ALL;
RTRV-COND-ALL;
If yes, go to step 4.
If no, go to step 5.
for module with FRCDWKSWPR or MANWKSWPR alarm.
RTRV-EQPT::AID;
If IS,STBYH, go to step 10.
If OOS-MA, go to step 7.
If yes, go to step 8.
If no, go to step 15.