Samsung AR07TSFABWKN Service Manual page 83

Multi air conditioner
Hide thumbs Also See for AR07TSFABWKN:
Table of Contents

Advertisement

4-6-1-3 Communication error after finishing Tracking
4Way
Indoor unit display
1Way
Console
Symptom
Failure
Is there a response from the indoor PCB?
(LED01 (RED) is not ON)
Remove the communication cable
connecting the outdoor unit to indoor unit,
and measure the signal on LINE 2 of the
outdoor unit with a scope
voltage waveform between the lines square
wave with amplitude over ±0.7V as shown
in the following picture?
Reconnect the cable connecting
the outdoor unit to the indoor unit
If the communication still doesn't work,
replace the indoor unit PCB.
+0.7V
-0.7V
Samsung Electronics
X (Operation)
X (Operation)
X (Operation)
Communication error between the indoor and outdoor unit for two minutes
Communication error between the indoor unit and outdoor unit
Yes
In this case, is the
Yes
and restart the unit.
Good
(Defrost)
(Timer) X (Filter)
(Timer)
(Fan)
X (Defrost)
(Timer)
No
LED01
X (Filter)
(Fan)
X (Filter)
Check the communication cable and
replace the indoor unit PCB
No
Check the communication
cable in the outdoor unit PCB
and replace the PCB
Bad
Troubleshooting