■ Combination Guide for Installation including AJ***BNHDCH / AJ***BNZDCH
- Only one AJ***BNZDCH (MPAH) indoor unit can be included in the combination.
CAUTION
- AJ***BNHDCH (Duct S) indoor units cannot be connected to outdoor unit model AJ020BXJ2CH.
- If AJ***BNHDCH and AC***BNZDCH indoor units are included in the combination, total sum of indoor unit index must be configured so as not to exceed the outdoor index.
- If the indoor unit combination includes AJ***BNHDCH / AC***BNZDCH indoor units and does not meet the installation combination restrictions, E563 error will display and the system will not operate.
. If error code E563 occurs, Cool Mode Try run and Pipe Check operations are still possible.
Combination Guide for Installation including AJ***BNHDCH / AC***BNZDCH
Mixed
4rooms
Outdoor Unit
Installation
Installation
AJ024BXJ3CH
Enabled
N/A
AJ036BXJ4CH
Enabled
N/A
AJ048BXJ5CH
Enabled
N/A
AJ020BXS3CH
Enabled
N/A
AJ024BXS4CH
Enabled
N/A
AJ030BXS4CH
Enabled
N/A
AJ036BXS4CH
Enabled
N/A
*Mixed installation means the case of mixing AJ***BNHDCH and AC***BNZDCH.