Download Print this page

Electrical Box - Daikin RKS18JV2S Service Manual

4.0/4.5/5.0/6.0 kw class 18000 btu/h class

Advertisement

Electrical Box

3. Electrical Box
Warning
Step
1
Remove the 2 screws
and remove the
protection plate.
2
Remove the 3 screws
and remove the wire
fixture.
3
Remove the 7 screws
and remove the
connecting wire and the
power supply wire.
4
Remove the 2 screws
and remove the earth /
ground wire.
6
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
1
2
3
Wire
fixture
Connecting wire
Power supply wire
Protection plate
(R18902)
(R18661)
(R16914)
Earth / ground wire
(R18957)
Si001274EC
Points
Removal Procedure

Hide quick links: