Download Print this page

Outdoor Fan / Fan Motor - Daikin RKS18JV2S Service Manual

4.0/4.5/5.0/6.0 kw class 18000 btu/h class

Advertisement

Outdoor Fan / Fan Motor

2. Outdoor Fan / Fan Motor
Warning
Step
1
Remove the shield
plate.
2
Disconnect the
connector [S70].
3
Release the clamp from
the partition plate.
4
Release the fan motor
lead wire from the
groove and the 2 hooks
of the partition plate.
5
Remove the nut and
remove the outdoor fan.
4
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
Ferrite core
Hook
Clamp
Nut
Outdoor fan
Shield plate
(R16785)
[S70]
(R16951)
Groove
Partition plate
(R18900)
(R18901)
Si001274EC
Points
[S70] : fan motor
The ferrite core of the fan
motor lead wire has a clamp.
Nut size: M6
10 mm
(0.39 inch)
(R18954)
When reassembling, align
the
mark of the outdoor
fan with the D-cut section of
the motor shaft.
Removal Procedure

Hide quick links:

Advertisement