Step
22 Release the harness of
the relay connector
from the wire saddle.
23 Pull out the clamp from
the partition plate.
24 Disconnect the
connector [S90].
25
Pull out the clamp.
26
Remove the wire
saddle.
Removal Procedure
Procedure
[S90]
Wire
saddle
Points
(R14313)
(R16950)
[S90]: thermistors
When reassembling, pass
the thermistor harness under
the harnesses (HL2: blue,
HN2: white) from the filter
PCB.
When reassembling, insert
the clamp as below.
(R16806)
(R22532)
Electrical Box
Thermistor
harnesses
(R16958)