Daikin RKS18JV2S Service Manual page 10

4.0/4.5/5.0/6.0 kw class 18000 btu/h class

Advertisement

Electrical Box
Step
8
Cut the clamp.
9
Pull out the outdoor
heat exchanger
thermistor.
10 Disconnect the
connector [S70].
11
Release the clamp from
the partition plate.
12
Release the fan motor
lead wire from the
groove and the 2 hooks
of the partition plate.
8
Procedure
Outdoor
heat
exchanger
thermistor
Ferrite core
Partition plate
Hook
Clamp
The position of the clamp
varies depending on the
model.
(R16766)
The position of the outdoor
heat exchanger thermistor
varies depending on the
model.
Be careful not to lose the clip
for the thermistor.
(R16819)
[S70]: fan motor
[S70]
(R16951)
The ferrite core of the fan
Groove
motor lead wire has a clamp.
(R18900)
Si001274EC
Points
Clip
(R3264)