Cleaning The Freezer; Disassembly Of Freezer Parts - Stoelting E131I Owner's Manual

Table of Contents

Advertisement

After the auger drive motor starts, there is a 3
second delay before the compressor starts.
B. Place the FREEZING CYLINDER OFF-ON
switch in the ON position and push the CLEAN switch
to rotate the auger. Allow the mix to agitate in the
freezer barrel until the mix has become a liquid,
about 5 minutes.
C. Drain the liquid mix by opening the spigot. A bucket
or container should be placed under the spigot to
catch the liquid mix (Fig. 16).
Figure 16. Draining Mix
D. Place the Freezing Cylinder OFF-ON switch in the
OFF position.

3.7 CLEANING THE FREEZER

The frequency of cleaning the freezer and
freezer parts must comply with state and local
health regulations.
After the mix has been removed from the freezer , the
freezer must be cleaned. T o clean the freezer, refer to
the following steps:
A. Close the spigot and fill the hopper with 2 gallons
(7.5 liters) of cold tap water.
B. Place the FREEZING CYLINDER OFF-ON switch in
the ON position while pushing the CLEAN switch to
rotate the auger.
C. Allow the water to agitate for approximately five
minutes.
If freezer is left in CLEAN for more than 30
minutes, it will go into error . Turn the FREEZING
CYLINDER OFF-ON switch OFF for 10 sec-
onds to clear the error.
NOTE
NOTE
NOTE
D. Open the spigot to drain the water . Remember to
place a bucket or container under the spigot to catch
the water. When the water has drained, turn the
FREEZING CYLINDER OFF-ON switch to the OFF
position. Allow the freezer barrel to drain completely .
E. Repeat steps A through D using a mild detergent
solution.
3.8 DISASSEMBLY OF FREEZER P ARTS
Hazardous Moving Parts
Revolving auger shaft can grab and cause injury.
FREEZING CYLINDER OFF-ON
Place the
switch
in the OFF position before disassembling
for cleaning or servicing.
Inspection for worn or broken parts should be made at
every disassembly of the freezer for cleaning or other
purposes. All worn or broken parts should be replaced to
ensure safety to both the operator and the customer and
to maintain good freezer performance and a quality
product. Two normal wear areas are the auger flights
and front auger support bushing (Fig. 17). Frequency of
cleaning must comply with the state and local health
regulations.
Figure 17. Auger Flight Wear and Front Auger
Support Bushing Wear
D. Place the FREEZING CYLINDER OFF-ON switch in
the OFF position.
To disassemble the freezer , refer to the following step s:
A. Remove the mix inlet regulator from the hopper by
pulling straight up.
B. Remove the front door by turning off the circular
knobs and then pulling the front door off the studs
(Fig. 18).
12
CAUTION

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

F131i