Hob power limitation
The induction hob is configured to
operate at 7.4 kW, but it can be
set to operate at 4.8 kW or 3.7
kW.
1. Disconnect the appliance from the mains
power supply and wait 10 seconds
before turning the power back on.
The power level of the hob must be
set within 2 minutes of it being
connected to the mains power
supply.
2. Turn the front left and front right cooking
zone knobs anticlockwise at the same
time (to position "M-A" and "A"
respectively), and keep them in this
position for 3 seconds.
The rear left and rear right cooking zone
displays will indicate "7." and "4".
3. Release the knobs.
4. Turn and hold both knobs anti-clockwise
again.
The rear left and rear right cooking zone
displays will indicate the power levels "4."
and "8".
5. Release the knobs.
6. Turn and hold both knobs anti-clockwise
again.
66
Use
The rear left and rear right cooking zone
displays will indicate the power levels "3."
and "7".
7. Release the knob.
After having released the knobs at
the required power level, wait until
the displays turn off.
The power level can be changed
again up to 4 minutes after the
displays have turned off (without
having to disconnect the appliance
from the power supply).
The last power setting will remain
selected even in the event of a
power failure.
Controls lock
The controls lock is a device that
protects the appliance from
accidental or inappropriate use.
1. With all cooking zones off,
simultaneously turn the two front right
and rear right cooking zone control
knobs anti-clockwise (position A).
2. Keep them turned until the
appear on the display.
3. Release the knobs.
In order to remove the control lock repeat
the same operations described previously.
If the knobs have been kept turned
to the A position for more than 30
seconds, the following fault
message
display.
symbols