Download Print this page

Error Messages - Sony BKS-R3210 Operation Manual

X-y control unit
Hide thumbs Also See for BKS-R3210:

Advertisement

Error Messages

While trouble occurs on this unit, the following error
messages appear in the preset display window.
Error messages Contents
Pac Err
Reception error on the S-BUS data link
Reset-P
The primary station has been reset.
Secret
A source set as secret is to be selected.
Com Err
Transmission error of the S-BUS data link This may occur when the communication period is too long.
Protect
The destination is protected.
Not found
The name cannot be found.
Lvl Err
All levels are not controllable.
No Dest
The destination has not been set.
Remarks
If this occurs only once every several minutes, it is not a
problem. Power source noise or an S-BUS remote cable
longer than 500 m using BELDEN cable or equivalent may be
the cause. If the same errors still occurs on this unit when
used under conditions without the above causes, the trouble
may be in this unit.
This occurs when the primary station is turned on, or when
some trouble occurs in the S-BUS data link.
A source set as secret cannot be selected on a unit other than
the primary station.
The primary station may be turned off, or the remote cable may
be disconnected.
The protected destination cannot be switched.
The designated type name for type-number selection does not
exist in the table.
All levels are set not to be controlled.
The designated destination has not been set. Change the
selection or setting.
17 (E)

Advertisement