3. DISPLAY AND OPERATION SECTIONS
Name
Software version - Lower
Software version - Upper
Automatic VC offset (Note)
Servo motor series ID
Servo motor type ID
Servo motor encoder ID
For manufacturer adjustment
For manufacturer adjustment
Teaching function
Note. Even if VC automatic offset is performed and 0 V is inputted, the speed may not completely be the set value.
Display
Refer to section 3.10.
3 - 13
Description
Indicates the version of the software.
Indicates the system number of the software.
If offset voltages in the analog circuits inside and
outside the servo amplifier cause the servo motor
setting speed not to be the designated value at VC
(Analog override) of 0 V, a zero-adjustment of offset
voltages will be automatically performed. When
using the VC automatic offset, enable it in the
following procedures. When it is enabled, [Pr. PC37]
value changes to the automatically adjusted offset
voltage.
1) Press the "SET" once.
2) Set the number in the first digit to 1 with
"UP"/"DOWN".
3) Press the "SET".
This function cannot be used if the input voltage of
VC is - 0.4 V or less, or + 0.4 V or more.
Push the "SET" button to show the series ID of the
servo motor currently connected.
For indication details, refer to appendix 1 of "Servo
Motor Instruction Manual (Vol. 3)".
Push the "SET" button to show the type ID of the
servo motor currently connected.
For indication details, refer to appendix 1 of "Servo
Motor Instruction Manual (Vol. 3)".
Push the "SET" button to show the encoder ID of
the servo motor currently connected.
For indication details, refer to appendix 1 of "Servo
Motor Instruction Manual (Vol. 3)".
This is for manufacturer adjustment.
This is for manufacturer adjustment.
After an operation travels to a target position
(MEND (Travel completion) is turned on) with a JOG
operation or manual pulse generator operation,
pushing the "SET" button of the operation part or
turning on TCH (Teach) will import position data.
This function is available only in the point table
method. For other control mode, the display remains
the same.