7. PARAMETERS
No./
Setting
symbol/name
digit
PC14
_ _ x x
Analog monitor 1 output selection
MOD1
Select a signal to output to MO1 (Analog monitor 1). Refer to appendix 8 (3) of
"MR-J4-_A_(-RJ) Servo Amplifier Instruction Manual" for detection point of output
Analog
selection.
monitor 1
output
Refer to table 7.8 for settings.
_ x _ _ For manufacturer setting
x _ _ _
Setting
Note 1. Items with
Table 7.8 Analog monitor setting value
value
00
(Linear) servo motor speed
(±8 V/max. speed)
01
Torque or thrust
(±8 V/max. torque or max. thrust) (Note 3)
02
(Linear) servo motor speed
(+8V/max. speed)
03
Torque or thrust
(+8 V/max. torque or max. thrust) (Note 3)
04
Current command (±8 V/max. current command)
05
Command pulse frequency (±10 V/±4 Mpulses/s)
06
Servo motor-side droop pulses (±10 V/100 pulses) (Note
2)
07
Servo motor-side droop pulses (±10 V/1000 pulses)
(Note 2)
08
Servo motor-side droop pulses (±10 V/10000 pulses)
(Note 2)
09
Servo motor-side droop pulses (±10 V/100000 pulses)
(Note 2)
0A
Feedback position (±10 V/1 Mpulses) (Note 2)
0B
Feedback position (±10 V/10 Mpulses) (Note 2)
0C
Feedback position (±10 V/100 Mpulses) (Note 2)
0D
Bus voltage (200 V class and 100 V class: +8 V/400 V,
400 V class: +8 V/800 V)
0E
Speed command 2 (±8 V/max. speed)
10
Load-side droop pulses (±10 V/100 pulses) (Note 2)
11
Load-side droop pulses (±10 V/1000 pulses) (Note 2)
12
Load-side droop pulses (±10 V/10000 pulses) (Note 2)
13
Load-side droop pulses (±10 V/100000 pulses) (Note 2)
14
Load-side droop pulses (±10 V/1 Mpulses) (Note 2)
15
Servo motor-side/load-side position deviation
(±10 V/100000 pulses)
16
Servo motor-side/load-side speed deviation
(±8 V/max. speed)
17
Encoder inside temperature (±10 V/±128 ˚C)
are available for each operation mode.
Standard: Standard (semi closed loop system) use of the rotary servo motor
Full.: Fully closed loop system use of the rotary servo motor
Lin.: Linear servo motor use
DD: Direct drive (DD) motor use
2. Encoder pulse unit
3. 8 V is outputted at the maximum torque. However, when [Pr. PA11] and [Pr. PA12] are set to limit
torque, 8 V is outputted at the torque highly limited.
Function
Item
7 - 43
Initial
Control mode
value
CP CL PS
[unit]
00h
0h
0h
Operation
mode (Note 1)